NDT for concrete under accelerated freeze/thaw tests and surface scaling

Romero Mendoza, Héctor Leonardo; Casati Calzada, María Jesús y Gálvez Ruíz, Jaime (2011). NDT for concrete under accelerated freeze/thaw tests and surface scaling. En: "fib Symposium 2011 in Prague: Concrete engineering for excellence and efficiency", 08/06/2011 - 10/06/2011, Praga, República Checa.

Descripción

Título: NDT for concrete under accelerated freeze/thaw tests and surface scaling
Autor/es:
  • Romero Mendoza, Héctor Leonardo
  • Casati Calzada, María Jesús
  • Gálvez Ruíz, Jaime
Tipo de Documento: Ponencia en Congreso o Jornada (Artículo)
Título del Evento: fib Symposium 2011 in Prague: Concrete engineering for excellence and efficiency
Fechas del Evento: 08/06/2011 - 10/06/2011
Lugar del Evento: Praga, República Checa
Título del Libro: Proceedings of fib Symposium 2011 in Prague: Concrete engineering for excellence and efficiency
Fecha: 2011
Materias:
Escuela: E.T.S.I. Caminos, Canales y Puertos (UPM)
Departamento: Ingeniería Civil: Construcción
Licencias Creative Commons: Reconocimiento - Sin obra derivada - No comercial

Texto completo

[img]
Vista Previa
Pdf - Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (771kB) | Vista Previa

Resumen

Freezing of water or salt solution in concrete pores is a main cause for severe damage and significant reduction of the service life. Most of the freeze-thaw (F-T) accelerated tests measure the scaling of concrete by weighting. This paper presents complementary procedures based on the use of strain gages and ultrasonic pulse velocity (UPV) for measuring the deterioration of concrete due to freezing and thawing. These non-destructive testing (NDT) procedures are applied to two types of concretes, one susceptible to F-T damage and the other does not. The results show a good correlation between scaling and the measurements obtained with NDT. Showing NDT the advantage to detect before the damage and to perform continuous measurement

Más información

ID de Registro: 12542
Identificador DC: http://oa.upm.es/12542/
Identificador OAI: oai:oa.upm.es:12542
Depositado por: Memoria Investigacion
Depositado el: 07 Ago 2012 09:51
Ultima Modificación: 21 Abr 2016 11:48
  • Open Access
  • Open Access
  • Sherpa-Romeo
    Compruebe si la revista anglosajona en la que ha publicado un artículo permite también su publicación en abierto.
  • Dulcinea
    Compruebe si la revista española en la que ha publicado un artículo permite también su publicación en abierto.
  • Recolecta
  • e-ciencia
  • Observatorio I+D+i UPM
  • OpenCourseWare UPM