Design, manufacturing and measurements of a metal-less V-groove RXI collimator

Grabovičkić, Dejan; Miñano Dominguez, Juan Carlos; Benitez Gimenez, Pablo; Cocho, Cristina y Buljan, Marina (2011). Design, manufacturing and measurements of a metal-less V-groove RXI collimator. En: "Nonimaging Optics: Efficient Design for Illumination and Solar Concentration VIII", 21/08/2011 - 22/08/2011, San Diego, EEUU. pp. 1-10.

Descripción

Título: Design, manufacturing and measurements of a metal-less V-groove RXI collimator
Autor/es:
  • Grabovičkić, Dejan
  • Miñano Dominguez, Juan Carlos
  • Benitez Gimenez, Pablo
  • Cocho, Cristina
  • Buljan, Marina
Tipo de Documento: Ponencia en Congreso o Jornada (Artículo)
Título del Evento: Nonimaging Optics: Efficient Design for Illumination and Solar Concentration VIII
Fechas del Evento: 21/08/2011 - 22/08/2011
Lugar del Evento: San Diego, EEUU
Título del Libro: Proceedings of Nonimaging Optics: Efficient Design for Illumination and Solar Concentration VIII
Fecha: 2011
Materias:
Escuela: Centro de Domótica Integral (CeDInt) (UPM)
Departamento: Otro
Licencias Creative Commons: Reconocimiento - Sin obra derivada - No comercial

Texto completo

[img]
Vista Previa
PDF (Document Portable Format) - Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (2MB) | Vista Previa

Resumen

A metal-less RXI collimator has been designed. Unlike to the conventional RXI collimators, whose back surface and central part of the front surface have to be metalized, this collimator does not include any mirrored surface. The back surface is designed as a grooved surface providing two TIR reflections for all rays impinging on it. The main advantage of the presented design is lower manufacturing cost since there is no need for the expensive process of metalization. Also, unlike to the conventional RXI collimators this design performs good colour mixing. The first prototype of V-groove RXI collimator has been made of PMMA by direct cutting using a five axis diamond turning machine. The experimental measurements of the first prototype are presented.

Más información

ID de Registro: 12873
Identificador DC: http://oa.upm.es/12873/
Identificador OAI: oai:oa.upm.es:12873
URL Oficial: http://proceedings.spiedigitallibrary.org/article.aspx?articleid=1341515
Depositado por: Memoria Investigacion
Depositado el: 08 Nov 2012 12:31
Ultima Modificación: 21 Abr 2016 12:11
  • Open Access
  • Open Access
  • Sherpa-Romeo
    Compruebe si la revista anglosajona en la que ha publicado un artículo permite también su publicación en abierto.
  • Dulcinea
    Compruebe si la revista española en la que ha publicado un artículo permite también su publicación en abierto.
  • Recolecta
  • e-ciencia
  • Observatorio I+D+i UPM