Banco de medidas automático para linealización de amplificadores

Torres Lopez-Sepulveda, Javier; Rodríguez Caudevilla, Miguel; Pardo Martin, José Manuel; Ortega González, Francisco Javier y Benavente Peces, César (2011). Banco de medidas automático para linealización de amplificadores. En: "XXVI Congreso de la URSI", 07/09/2011 - 09/09/2011, Leganés, Madrid, España. pp. 1-4.

Descripción

Título: Banco de medidas automático para linealización de amplificadores
Autor/es:
  • Torres Lopez-Sepulveda, Javier
  • Rodríguez Caudevilla, Miguel
  • Pardo Martin, José Manuel
  • Ortega González, Francisco Javier
  • Benavente Peces, César
Tipo de Documento: Ponencia en Congreso o Jornada (Artículo)
Título del Evento: XXVI Congreso de la URSI
Fechas del Evento: 07/09/2011 - 09/09/2011
Lugar del Evento: Leganés, Madrid, España
Título del Libro: Actas del XXVI Congreso de la URSI
Fecha: 2011
Materias:
Escuela: E.U.I.T. Telecomunicación (UPM) [antigua denominación]
Departamento: Ingeniería Audiovisual y Comunicaciones [hasta 2014]
Licencias Creative Commons: Reconocimiento - Sin obra derivada - No comercial

Texto completo

[img]
Vista Previa
PDF (Document Portable Format) - Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (520kB) | Vista Previa

Resumen

This work is focused on building and configuring a measurement test bench for non linear High Power Amplifiers, more precisely those ones based on the Envelope Elimination and Restoration. At first sight the test bench is composed of several arbitrary waveform generators, an oscilloscope, a vector signal generator and a spectrum analyzer all of them controlled remotely. The test bench works automatically, that is why several software control programs have been developed in order to control all this equipment. The control programs have been developed in Matlab/Octave Scripting language and at last chance in a more low level language as C. The signal processing algorithms, taking into account that the time alignment one is the most important, have been developed in Matlab/Octave Scripting too. An improvement of 10dB in the ACPR(Adjacent Channel Power Ratio) has been obtained just by applying the time alignment algorithm developed in this work

Más información

ID de Registro: 13040
Identificador DC: http://oa.upm.es/13040/
Identificador OAI: oai:oa.upm.es:13040
URL Oficial: http://www.ursi2011.org/
Depositado por: Memoria Investigacion
Depositado el: 05 Dic 2012 10:48
Ultima Modificación: 21 Abr 2016 12:20
  • Open Access
  • Open Access
  • Sherpa-Romeo
    Compruebe si la revista anglosajona en la que ha publicado un artículo permite también su publicación en abierto.
  • Dulcinea
    Compruebe si la revista española en la que ha publicado un artículo permite también su publicación en abierto.
  • Recolecta
  • e-ciencia
  • Observatorio I+D+i UPM