Timing performances of a data acquisition system for time of flight PET

Morrocchi, Matteo; Marcatili, Sara; Belcari, Nicola; Bisogni, Maria Giuseppina; Collazuol, Gianmaria; Ambrosi, Giovanni; Corsi, Francesco; Foresta, Maurizio; Marzocca, Cristoforo; Matarrese, Gianvito; Sportelli, Giancarlo; Guerra Gutiérrez, Pedro; Santos Lleo, Andres de y Guerra, Alberto del (2012). Timing performances of a data acquisition system for time of flight PET. "Nuclear Instruments and Methods in Physics Research Section A: Accelerators Spectrometers, Detectors and Associated Equipment", v. 695 ; pp. 210-212. ISSN 0168-9002. https://doi.org/10.1016/j.nima.2011.11.073.

Descripción

Título: Timing performances of a data acquisition system for time of flight PET
Autor/es:
  • Morrocchi, Matteo
  • Marcatili, Sara
  • Belcari, Nicola
  • Bisogni, Maria Giuseppina
  • Collazuol, Gianmaria
  • Ambrosi, Giovanni
  • Corsi, Francesco
  • Foresta, Maurizio
  • Marzocca, Cristoforo
  • Matarrese, Gianvito
  • Sportelli, Giancarlo
  • Guerra Gutiérrez, Pedro
  • Santos Lleo, Andres de
  • Guerra, Alberto del
Tipo de Documento: Artículo
Título de Revista/Publicación: Nuclear Instruments and Methods in Physics Research Section A: Accelerators Spectrometers, Detectors and Associated Equipment
Fecha: Diciembre 2012
Volumen: 695
Materias:
Palabras Clave Informales: Positron emission tomography; Acquisition system; Silicon photomultiplier; Radiation Detector
Escuela: E.T.S.I. Telecomunicación (UPM)
Departamento: Ingeniería Electrónica
Licencias Creative Commons: Reconocimiento - Sin obra derivada - No comercial

Texto completo

[img]
Vista Previa
PDF (Document Portable Format) - Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (530kB) | Vista Previa

Resumen

We are investigating the performances of a data acquisition system for Time of Flight PET, based on LYSO crystal slabs and 64 channels Silicon Photomultipliers matrices (1.2 cm2 of active area each). Measurements have been performed to test the timing capability of the detection system (SiPM matices coupled to a LYSO slab and the read-out electronics) with both test signal and radioactive source.

Más información

ID de Registro: 15978
Identificador DC: http://oa.upm.es/15978/
Identificador OAI: oai:oa.upm.es:15978
Identificador DOI: 10.1016/j.nima.2011.11.073
URL Oficial: http://www.sciencedirect.com/science/article/pii/S0168900211021413#
Depositado por: Memoria Investigacion
Depositado el: 29 Jun 2013 07:42
Ultima Modificación: 01 Ene 2015 23:56
  • Open Access
  • Open Access
  • Sherpa-Romeo
    Compruebe si la revista anglosajona en la que ha publicado un artículo permite también su publicación en abierto.
  • Dulcinea
    Compruebe si la revista española en la que ha publicado un artículo permite también su publicación en abierto.
  • Recolecta
  • e-ciencia
  • Observatorio I+D+i UPM
  • OpenCourseWare UPM