Calculation of Response matrix of a BSS with 6LiI scintillator

Vega-Carrillo, Héctor René; Donaire, I.; Gallego Díaz, Eduardo F.; Manzanares-Acuña, Eduardo; Lorente Fillol, Alfredo; Iñiguez Gonzalez, Guillermo; Martín Martín, Alonso y Gutiérrez Villanueva, José Luis (2008). Calculation of Response matrix of a BSS with 6LiI scintillator. "Revista Mexicana de Fisica", v. S 54 (n. 1); pp. 57-62. ISSN 0035-001X.

Descripción

Título: Calculation of Response matrix of a BSS with 6LiI scintillator
Autor/es:
  • Vega-Carrillo, Héctor René
  • Donaire, I.
  • Gallego Díaz, Eduardo F.
  • Manzanares-Acuña, Eduardo
  • Lorente Fillol, Alfredo
  • Iñiguez Gonzalez, Guillermo
  • Martín Martín, Alonso
  • Gutiérrez Villanueva, José Luis
Tipo de Documento: Artículo
Título de Revista/Publicación: Revista Mexicana de Fisica
Fecha: Febrero 2008
Volumen: S 54
Materias:
Palabras Clave Informales: Monte Carlo, 6LiI scintillator, bonner sphere neutron spectrometer.
Escuela: E.T.S.I. Industriales (UPM)
Departamento: Ingeniería Nuclear [hasta 2014]
Licencias Creative Commons: Reconocimiento - Sin obra derivada - No comercial

Texto completo

[img]
Vista Previa
PDF (Document Portable Format) - Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (332kB) | Vista Previa

Resumen

The response matrix of a Bonner sphere spectrometer was calculated using MCNP 4C and MCNPX 2.4.0 codes. As thermal neutron detector a 0.4 cm £; 0.4 cm 6LiI which is located at the center of a set of polyethylene spheres. The response was calculated for 0, 2, 3, 5, 8, 10, and 12 inches-diameter polyethylene spheres for neutrons whose energy goes from 2.50E(-8) to 100 MeV. The response matrix was calculated for 23 neutron energies, the response functions were energy-interpolated to 51 neutron energies and were compared with a matrix response reported in the literature, in this comparison both response matrices are in agreement. The main differences were found in the bare detector and are attributed to the irradiation conditions and cross sections, for the other detectors the differences are due to the cross sections libraries.

Más información

ID de Registro: 3045
Identificador DC: http://oa.upm.es/3045/
Identificador OAI: oai:oa.upm.es:3045
URL Oficial: http://rmf.fciencias.unam.mx/pdf/rmf-s/54/1/54_1_057.pdf
Depositado por: Memoria Investigacion
Depositado el: 07 May 2010 11:03
Ultima Modificación: 20 Abr 2016 12:37
  • Open Access
  • Open Access
  • Sherpa-Romeo
    Compruebe si la revista anglosajona en la que ha publicado un artículo permite también su publicación en abierto.
  • Dulcinea
    Compruebe si la revista española en la que ha publicado un artículo permite también su publicación en abierto.
  • Recolecta
  • e-ciencia
  • Observatorio I+D+i UPM
  • OpenCourseWare UPM