Full text
|
PDF
- Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (1MB) | Preview |
Vega Ramiro, Enrique and Pindado Carrion, Santiago and Martínez Muelas, Alejandro and Meseguer, Encarnación and García Díaz, Luis (2014). Anomaly detection on cup anemometers. "Measurement Science and Technology", v. 25 ; pp. 127002-1. ISSN 0957-0233. https://doi.org/10.1088/0957-0233/25/12/127002.
Title: | Anomaly detection on cup anemometers |
---|---|
Author/s: |
|
Item Type: | Article |
Título de Revista/Publicación: | Measurement Science and Technology |
Date: | November 2014 |
ISSN: | 0957-0233 |
Volume: | 25 |
Subjects: | |
Freetext Keywords: | anemometer calibration, cup anemometer, cup aerodynamics, rotor aerodynamics, anomaly detection, Fourier analysis, Vector Instruments A100 LK |
Faculty: | Instituto de Microgravedad Ignacio Da Riva (UPM) |
Department: | Infraestructura, Sistemas Aeroespaciales y Aeropuertos [hasta 2014] |
UPM's Research Group: | Desarrollo y Ensayos Aeroespaciales |
Creative Commons Licenses: | Recognition - No derivative works - Non commercial |
|
PDF
- Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (1MB) | Preview |
The performances of two rotor-damaged commercial anemometers (Vector Instruments A100 LK) were studied. The calibration results (i.e. the transfer function) were very linear, the aerodynamic behavior being more efficient than the one shown by both anemometers equipped with undamaged rotors. No detection of the anomaly (the rotors'damage) was possible based on the calibration results. However, the Fourier analysis clearly revealed this anomaly.
Item ID: | 32996 |
---|---|
DC Identifier: | http://oa.upm.es/32996/ |
OAI Identifier: | oai:oa.upm.es:32996 |
DOI: | 10.1088/0957-0233/25/12/127002 |
Official URL: | http://iopscience.iop.org/0957-0233/25/12/127002/article |
Deposited by: | Biblioteca ETSI Aeronauticos |
Deposited on: | 04 Dec 2014 11:00 |
Last Modified: | 17 Jan 2017 12:18 |