Experimental analysis of energy savings and hygrothermal conditions improvement by means of air curtaines in stores with intensive pedestrian traffic

Gil López, Tomás; Gálvez Huerta, Miguel Ángel; Castejón Navas, Juan y Gómez García, Virginia (2013). Experimental analysis of energy savings and hygrothermal conditions improvement by means of air curtaines in stores with intensive pedestrian traffic. "Energy And Buildings", v. 67 ; pp. 608-615. ISSN 0378-7788. https://doi.org/10.1016/j.enbuild.2013.08.058.

Descripción

Título: Experimental analysis of energy savings and hygrothermal conditions improvement by means of air curtaines in stores with intensive pedestrian traffic
Autor/es:
  • Gil López, Tomás
  • Gálvez Huerta, Miguel Ángel
  • Castejón Navas, Juan
  • Gómez García, Virginia
Tipo de Documento: Artículo
Título de Revista/Publicación: Energy And Buildings
Fecha: Diciembre 2013
Volumen: 67
Materias:
Palabras Clave Informales: Climatic separation; Air curtains; Direct expansion systems; Energy savings; Stores air conditioning; Warm humid climates
Escuela: E.U. de Arquitectura Técnica (UPM) [antigua denominación]
Departamento: Otro
Licencias Creative Commons: Reconocimiento - Sin obra derivada - No comercial

Texto completo

[img]
Vista Previa
PDF (Document Portable Format) - Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (954kB) | Vista Previa

Resumen

Current worldwide building legislation requirements aim to the design and construction of technical services that reduce energy consumption and improve indoor hygrothermal conditions. The retail sector in Spain, with a lot of outdated technical systems, demands energy conservation measures in order to reduce the increasingly electrical consumption for cooling. Climatic separation with modern air curtains and advanced hygrothermal control systems enables energy savings and can keep suitable indoor air temperature and humidity of stores with intense pedestrian traffic, especially when located in hot humid climates. As stated in the article, the energy savings in commercial buildings with these systems exceeds 30%

Más información

ID de Registro: 33516
Identificador DC: http://oa.upm.es/33516/
Identificador OAI: oai:oa.upm.es:33516
Identificador DOI: 10.1016/j.enbuild.2013.08.058
URL Oficial: http://www.sciencedirect.com/science/article/pii/S0378778813005550
Depositado por: Memoria Investigacion
Depositado el: 22 Abr 2015 08:07
Ultima Modificación: 22 Abr 2015 08:07
  • Open Access
  • Open Access
  • Sherpa-Romeo
    Compruebe si la revista anglosajona en la que ha publicado un artículo permite también su publicación en abierto.
  • Dulcinea
    Compruebe si la revista española en la que ha publicado un artículo permite también su publicación en abierto.
  • Recolecta
  • e-ciencia
  • Observatorio I+D+i UPM
  • OpenCourseWare UPM