Calibración de sensores de fuerza bajo estímulos sinusoidales: contribuciones a su caracterización

Medina Martín, Nieves (2015). Calibración de sensores de fuerza bajo estímulos sinusoidales: contribuciones a su caracterización. Thesis (Doctoral), E.T.S.I. Industriales (UPM).

Description

Title: Calibración de sensores de fuerza bajo estímulos sinusoidales: contribuciones a su caracterización
Author/s:
  • Medina Martín, Nieves
Contributor/s:
  • Vicente y Oliva, Jesus de
Item Type: Thesis (Doctoral)
Date: 2015
Subjects:
Faculty: E.T.S.I. Industriales (UPM)
Department: Física Aplicada e Ingeniería de Materiales
Creative Commons Licenses: Recognition - No derivative works - Non commercial

Full text

[img]
Preview
PDF - Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (3MB) | Preview

Abstract

El presente trabajo tiene como objetivo el desarrollo de un patrón primario para la calibración de sensores de fuerza bajo excitaciones sinusoidales. Con consecuencia de dicho desarrollo se establecerá un método de calibración de sensores de fuerza en condiciones dinámicas que permitirá la caracterización de estos sensores en dichas condiciones y determinar la incertidumbre asociada. Este patrón se basa en la definición directa de fuerza como masa por aceleración. Para ello se carga el sensor con distintas cargas calibradas y se somete a distintas aceleraciones mediante un excitador de vibraciones. Dichas aceleraciones se generan para frecuencias desde 5 Hz a 2400 Hz. La aceleración se mide mediante un vibrómetro láser con trazabilidad a la unidad de longitud (longitud de onda del láser). Al ser una medición completamente dinámica se necesita un sistema de adquisición de datos multicanal para la toma de datos en tiempo real. Este sistema adquiere las señales eléctricas provenientes del vibrómetro láser, del sensor a caracterizar y del acelerómetro para mediciones auxiliares. Se ha dispuesto de cuatro sensores de fuerza para realizar ensayos, un sensor piezoeléctrico y tres sensores resistivos. En este trabajo se han estudiado los factores de influencia y se ha implementado un método de calibración para minimizar los mismos, así como también se han establecido las correcciones a realizar. Para la caracterización dinámica del sensor se ha partido de un modelo de oscilador armónico amortiguado forzado, se ha establecido la metodología para la determinación de sus parámetros de caracterización y se ha estudiado su validez. También se ha realizado una comparación entre los resultados obtenidos para condiciones estáticas y dinámicas. ABSTRACT The aim in the current work is the development of a primary standard for force sensors calibration under sinusoidal excitations. As consequence of this development a method for force sensors calibration under dynamic conditions will be established that will allow these sensors characterization for such conditions and the determination of their associated uncertainty. This standard is based on the direct definition of force as mass multiplied by acceleration. To do so, the sensor is loaded with different calibrated loads and is maintained under different accelerations by means of a vibration shaker. These accelerations are generated with frequencies from 5 Hz up to 2400 Hz. The acceleration is measured by means of a laser vibrometer with traceability to the unit of length (laser wavelength). As the measurement is totally dynamic a multiple channel data acquisition system is required for data acquisition in real time. This system acquires the electrical signals outputs coming from the laser vibrometer, the sensor to be characterised and two accelerometers for additional measurements. Four force sensors, one piezoelectric sensor and three resistive sensors, have been available to perform the tests. During this work the influence factors have been studied and a calibration method to minimise these factors have been implemented as well as the corrections to be performed have been established. As the starting point for the sensor dynamic characterization, a model for a forced damped harmonic oscillator has been used, a method for the characterizing parameters determination has been established and its validity has been studied. A comparison between results for static and dynamic conditions has been performed as well.

More information

Item ID: 38243
DC Identifier: http://oa.upm.es/38243/
OAI Identifier: oai:oa.upm.es:38243
Deposited by: Archivo Digital UPM 2
Deposited on: 29 Oct 2015 08:43
Last Modified: 27 Apr 2016 22:56
  • Logo InvestigaM (UPM)
  • Logo GEOUP4
  • Logo Open Access
  • Open Access
  • Logo Sherpa/Romeo
    Check whether the anglo-saxon journal in which you have published an article allows you to also publish it under open access.
  • Logo Dulcinea
    Check whether the spanish journal in which you have published an article allows you to also publish it under open access.
  • Logo de Recolecta
  • Logo del Observatorio I+D+i UPM
  • Logo de OpenCourseWare UPM