Integrated slot-waveguide microresonator for biochemical sensing

Angulo Barrios, Carlos; Gylfason, Kristinn B.; Sánchez, Benito; Griol Barres, Amadeu; Holgado Bolaños, Miguel y Casquel del Campo, Rafael (2009). Integrated slot-waveguide microresonator for biochemical sensing. En: "EUROPTRODE IX", 30/03/2008-02/04/2008, Dublin (Irlanda). ISBN 0000-0000. pp..

Descripción

Título: Integrated slot-waveguide microresonator for biochemical sensing
Autor/es:
  • Angulo Barrios, Carlos
  • Gylfason, Kristinn B.
  • Sánchez, Benito
  • Griol Barres, Amadeu
  • Holgado Bolaños, Miguel
  • Casquel del Campo, Rafael
Tipo de Documento: Ponencia en Congreso o Jornada (Póster)
Título del Evento: EUROPTRODE IX
Fechas del Evento: 30/03/2008-02/04/2008
Lugar del Evento: Dublin (Irlanda)
Título del Libro: Proceedings of Europtrode IX
Fecha: 2009
ISBN: 0000-0000
Materias:
Escuela: E.T.S.I. Telecomunicación (UPM)
Departamento: Ingeniería Electrónica
Licencias Creative Commons: Reconocimiento - Sin obra derivada - No comercial

Texto completo

[img]
Vista Previa
PDF (Document Portable Format) - Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (58kB) | Vista Previa

Resumen

A novel integrated biochemical sensor based on a slot-waveguide [1] microring resonator is demonstrated. The microresonator is fabricated on a Si3N4/SiO2 material platform [2] by using conventional microfabrication techniques, such as Si thermal oxidation, chemical vapour deposition, electron-beam lithography and reactive ion etching. The sensor consists of a 70-μm-radius ring resonator formed by a slot-waveguide [1] having a slot-width of 200 nm. The operation wavelength is 1.3 μm. The device is exposed to different water-ethanol solutions and its transmission spectrum is measured. A linear shift of the resonant wavelength with increasing ambient refractive index of 212 nm/refractive index units (RIU) is observed. This value is more than twice larger than those of strip-waveguide ring resonator biochemical sensors, indicating that higher analyte-probe light interaction occurs in our slot-waveguide sensor as compared to those based on conventional strip waveguides. The sensor detects a minimal refractive index variation of 2x10-4 RIU, limited by the wavelength resolution of the light source (50 pm). Simulations indicate that the slot region is partially filled when the sensor is exposed to an aqueous solution. We also demonstrate the capability of our sensor to measure higher index fluids such as isopropanol (n=1.37) and cyclohexane (n=1.42).

Más información

ID de Registro: 3868
Identificador DC: http://oa.upm.es/3868/
Identificador OAI: oai:oa.upm.es:3868
URL Oficial: http://webpages.dcu.ie/~bdiconf/home.php
Depositado por: Memoria Investigacion
Depositado el: 26 Jul 2010 09:15
Ultima Modificación: 09 Mar 2016 12:39
  • Open Access
  • Open Access
  • Sherpa-Romeo
    Compruebe si la revista anglosajona en la que ha publicado un artículo permite también su publicación en abierto.
  • Dulcinea
    Compruebe si la revista española en la que ha publicado un artículo permite también su publicación en abierto.
  • Recolecta
  • e-ciencia
  • Observatorio I+D+i UPM
  • OpenCourseWare UPM