SOPHIA CPV module round robin: power rating at CSOC

Siefer, Gerald; Steiner, Marc; Baudrit, Mathieu; Domínguez Domínguez, César; Anton Hernandez, Ignacio; Nuñez Júdez, Rubén; Roca, Franco; Pugliatti, Paola Maria; Di Stefano, Agnese; Kenny, Robert y Morabito, Paolo (2014). SOPHIA CPV module round robin: power rating at CSOC. En: "10th International Conference on Concentrator Photovoltaic Systems: CPV-10", 7/04/2014–9/04/2014, Albuquerque, New Mexico, USA. ISBN 978-0-7354-1253-8. pp. 167-172.

Descripción

Título: SOPHIA CPV module round robin: power rating at CSOC
Autor/es:
  • Siefer, Gerald
  • Steiner, Marc
  • Baudrit, Mathieu
  • Domínguez Domínguez, César
  • Anton Hernandez, Ignacio
  • Nuñez Júdez, Rubén
  • Roca, Franco
  • Pugliatti, Paola Maria
  • Di Stefano, Agnese
  • Kenny, Robert
  • Morabito, Paolo
Tipo de Documento: Ponencia en Congreso o Jornada (Artículo)
Título del Evento: 10th International Conference on Concentrator Photovoltaic Systems: CPV-10
Fechas del Evento: 7/04/2014–9/04/2014
Lugar del Evento: Albuquerque, New Mexico, USA
Título del Libro: 10th International Conference on Concentrator Photovoltaic Systems - AIP Conference Proceedings
Título de Revista/Publicación: AIP Conference Proceedings
Fecha: 2014
ISBN: 978-0-7354-1253-8
Volumen: 1616
Materias:
Palabras Clave Informales: CPV modules; Performance testing; Standardization
Escuela: E.T.S.I. Diseño Industrial (UPM)
Departamento: Ingeniería Eléctrica, Electrónica Automática y Física Aplicada
Licencias Creative Commons: Reconocimiento - Sin obra derivada - No comercial

Texto completo

[img] PDF (Document Portable Format) - Acceso permitido solamente a usuarios en el campus de la UPM - Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (775kB)

Resumen

In the frame of the European project SOPHIA a concentrator photovoltaic (CPV) module measurement round robin has been initiated. The round robin includes measurements of four CPV modules at seven different test laboratories located in Europe. IV curves of the modules are measured with different measurement equipment under various climatic conditions. The aim of this activity is to perform at each site a rating of the modules at concentrator standard operating conditions CSOC according to IEC 62670-1. The outcome of the round robin is intended for direct feedback to the current draft standard IEC 62670-3 “Concentrator Photovoltaic (CPV) Performance Testing - Performance Measurements and Power Rating”. The paper discusses initial results from the first three partners that have already finished the measurements up to now.

Proyectos asociados

TipoCódigoAcrónimoResponsableTítulo
FP7262533SOPHIACommisariat a l' Energie Atomique et aux Energies AlternativesPhotovoltaic European Research Infrastructure

Más información

ID de Registro: 38848
Identificador DC: http://oa.upm.es/38848/
Identificador OAI: oai:oa.upm.es:38848
URL Oficial: http://scitation.aip.org/content/aip/proceeding/aipcp/10.1063/1.4897053
Depositado por: Memoria Investigacion
Depositado el: 08 Ene 2016 10:08
Ultima Modificación: 13 Mar 2017 08:53
  • Open Access
  • Open Access
  • Sherpa-Romeo
    Compruebe si la revista anglosajona en la que ha publicado un artículo permite también su publicación en abierto.
  • Dulcinea
    Compruebe si la revista española en la que ha publicado un artículo permite también su publicación en abierto.
  • Recolecta
  • e-ciencia
  • Observatorio I+D+i UPM
  • OpenCourseWare UPM