Análisis de la precisión de los resultados de medidas de potencia acústica de fuentes de referencia

González Pacheco, Alejandro (2016). Análisis de la precisión de los resultados de medidas de potencia acústica de fuentes de referencia. Thesis (Master thesis), E.T.S.I. y Sistemas de Telecomunicación (UPM).

Description

Title: Análisis de la precisión de los resultados de medidas de potencia acústica de fuentes de referencia
Author/s:
  • González Pacheco, Alejandro
Contributor/s:
  • Sancho Gil, Juan
Item Type: Thesis (Master thesis)
Masters title: Ingeniería Acústica de la Edificación y Medio Ambiente
Date: 17 June 2016
Subjects:
Faculty: E.T.S.I. y Sistemas de Telecomunicación (UPM)
Department: Teoría de la Señal y Comunicaciones
Creative Commons Licenses: Recognition - No derivative works - Non commercial

Full text

[img]
Preview
PDF - Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (1MB) | Preview
[img] Archive (ZIP) - Users in campus UPM only
Download (224kB)

Abstract

En la actualidad existen dos tipos de método con grado de precisión para la determinación de los niveles de potencia acústica de fuentes sonoras, los que se basan en medidas del nivel de presión acústica, y los basados en medidas de intensidad acústica. Este trabajo presenta los resultados del análisis comparativo realizado al aplicar los dos métodos estandarizados con grado de precisión que utilizan medidas de nivel de presión acústica, concretamente los establecidos en las normas internacionales ISO 3741 e ISO 3745. La principal diferencia entre los dos métodos es el recinto requerido para llevar a cabo las mediciones, siendo necesaria una cámara reverberante acondicionada en la que se pueda generar un campo sonoro prácticamente difuso, para realizar los ensayos según la Norma ISO 3741, y una cámara anecoica o semianecoica, que proporcione condiciones de campo libre, para llevar a cabo los ensayos según la Norma ISO 3745. Para medir el nivel de potencia acústica de las fuentes acústicas de referencia, el método favorito es el que emplea como recinto de ensayo una cámara semianecoica, y por tanto, aplica la Norma ISO 3745. Sin embargo, en este trabajo se demuestra que los resultados obtenidos aplicando uno u otro método son comparables en términos metrológicos y ambos presentan incertidumbres adecuadas, de acuerdo a la precisión establecida para cada uno de ellos. ABSTRACT. There are, nowadays, two different kinds of method with precision degree of accuracy for the determination of sound power level of noise sources, those which are based on sound pressure level measurements and those based on intensity measurements. This paper shows the results of the comparative analysis carried out by applying the two standardized methods with precision degree of accuracy using sound pressure level measurements, which are established in the international standards ISO 3741 and ISO 3745. The main difference between this two methods is the enclosure required to carry out the measurements, a specially adjusted reverberant room, where it is possible to generate a nearly diffuse sound field, for the tests according to ISO 3741, and, an anechoic or semi-anechoic chamber providing free field conditions in order to conduct the tests according to ISO 3745. When measuring the sound power level of reference sound sources, the preferred method is the one that needs a semi-anechoic chamber to perform the measurements, and therefore applies ISO 3745. However, in this paper, it is demonstrated that the results obtained using either method are comparable in metrological terms and both show suitable uncertainties, according to the accuracy established for each of them.

More information

Item ID: 43598
DC Identifier: http://oa.upm.es/43598/
OAI Identifier: oai:oa.upm.es:43598
Deposited by: Biblioteca Universitaria Campus Sur
Deposited on: 17 Oct 2016 08:59
Last Modified: 17 Oct 2016 08:59
  • Logo InvestigaM (UPM)
  • Logo GEOUP4
  • Logo Open Access
  • Open Access
  • Logo Sherpa/Romeo
    Check whether the anglo-saxon journal in which you have published an article allows you to also publish it under open access.
  • Logo Dulcinea
    Check whether the spanish journal in which you have published an article allows you to also publish it under open access.
  • Logo de Recolecta
  • Logo del Observatorio I+D+i UPM
  • Logo de OpenCourseWare UPM