Full model análisis of a radial line slot antena and efficiency assesment as functions of slot pair design

Sudo, Kaoru; Hirokawa, Jiro; Ando, Makoto y Sierra Castañer, Manuel (2004). Full model análisis of a radial line slot antena and efficiency assesment as functions of slot pair design. En: "XIX Simposium Nacional de la Unión Científica Internacional de Radio (URSI 2004)", 08/09/2004- 10/09/2004, Barcelona, España. pp. 1-4.

Descripción

Título: Full model análisis of a radial line slot antena and efficiency assesment as functions of slot pair design
Autor/es:
  • Sudo, Kaoru
  • Hirokawa, Jiro
  • Ando, Makoto
  • Sierra Castañer, Manuel
Tipo de Documento: Ponencia en Congreso o Jornada (Artículo)
Título del Evento: XIX Simposium Nacional de la Unión Científica Internacional de Radio (URSI 2004)
Fechas del Evento: 08/09/2004- 10/09/2004
Lugar del Evento: Barcelona, España
Título del Libro: XIX Simposium Nacional de la Unión Científica Internacional de Radio (URSI 2004)
Fecha: 2004
Materias:
Escuela: E.T.S.I. Telecomunicación (UPM)
Departamento: Señales, Sistemas y Radiocomunicaciones
Licencias Creative Commons: Reconocimiento - Sin obra derivada - No comercial

Texto completo

[img]
Vista Previa
PDF (Document Portable Format) - Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (420kB) | Vista Previa

Resumen

A full-model structure of CA-RLSA with feeder has been analyzed by using the MoM. The results of the calculated aperture-field show reasonable agreement with the experimental ones on the outermost round of slot pairs by the full-model analysis. We estimate effect of distance between slot pairs in φ-direction. As a result of design, enhance of the aperture efficiency is 2%. We propose a design method by using this full-model analysis. The ρ-positions of the slot pairs are adjusted respectively to suppress the deviation of the phase in the φ−direction. As a result of calculation in the 22 GHzband, dielectric constant εr=2.2, height h=3.2 mm, the three kind of parameters are determined as the aperture efficiency is high.

Más información

ID de Registro: 44118
Identificador DC: http://oa.upm.es/44118/
Identificador OAI: oai:oa.upm.es:44118
Depositado por: Memoria Investigacion
Depositado el: 19 Dic 2016 16:09
Ultima Modificación: 19 Dic 2016 16:09
  • Open Access
  • Open Access
  • Sherpa-Romeo
    Compruebe si la revista anglosajona en la que ha publicado un artículo permite también su publicación en abierto.
  • Dulcinea
    Compruebe si la revista española en la que ha publicado un artículo permite también su publicación en abierto.
  • Recolecta
  • e-ciencia
  • Observatorio I+D+i UPM
  • OpenCourseWare UPM