Characterization of the amplitude frequency response of Analog-to-Digital Converters

Díaz de Aguilar, J.; Salinas, J.R.; Lapuh, R.; Mendez Jaque, Angel; García Lagos, F. y Sanmamed, Y.A. (2016). Characterization of the amplitude frequency response of Analog-to-Digital Converters. En: "Conference on Precision Electromagnetic Measurements (CPEM 2016)", 10-15 Jul, Ottawa, Canada. ISBN 978-1-4673-9134-4. https://doi.org/10.1109/CPEM.2016.7540634.

Descripción

Título: Characterization of the amplitude frequency response of Analog-to-Digital Converters
Autor/es:
  • Díaz de Aguilar, J.
  • Salinas, J.R.
  • Lapuh, R.
  • Mendez Jaque, Angel
  • García Lagos, F.
  • Sanmamed, Y.A.
Tipo de Documento: Ponencia en Congreso o Jornada (Artículo)
Título del Evento: Conference on Precision Electromagnetic Measurements (CPEM 2016)
Fechas del Evento: 10-15 Jul
Lugar del Evento: Ottawa, Canada
Título del Libro: Precision Electromagnetic Measurements (CPEM 2016)
Fecha: 2016
ISBN: 978-1-4673-9134-4
Materias:
Palabras Clave Informales: Analog-to-Digital converter, Digital-to-Analog converter, thermal converter, AC quantum standard, Monte Carlo method, measurement uncertainty
Escuela: E.T.S. de Ingeniería Aeronáutica y del Espacio (UPM)
Departamento: Mecánica de Fluidos y Propulsión Aeroespacial
Licencias Creative Commons: Reconocimiento - Sin obra derivada - No comercial

Texto completo

[img]
Vista Previa
PDF (Document Portable Format) - Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (134kB) | Vista Previa

Resumen

This paper describes a method for the characterization of the amplitude frequency response of Analog-to-Digital converters at frequencies up to 20 kHz using a true quantum reference calibrated semiconductor based DAC arbitrary waveform generator, developed within the EMPIR project Q-WAVE, jointly founded by the European Union and the partipating countries. The procedure that can be used for the characterization of any ADC is appplied to de DCV function of a Keysight 3458A digital multimeter. The measurement conditions an the main uncertainty sources are identified and evaluated for complete uncertainty estimation by means of the Monte Carlo Method.

Más información

ID de Registro: 46596
Identificador DC: http://oa.upm.es/46596/
Identificador OAI: oai:oa.upm.es:46596
Identificador DOI: 10.1109/CPEM.2016.7540634
Depositado por: Memoria Investigacion
Depositado el: 24 Ene 2018 08:55
Ultima Modificación: 24 Ene 2018 08:55
  • GEO_UP4
  • Open Access
  • Open Access
  • Sherpa-Romeo
    Compruebe si la revista anglosajona en la que ha publicado un artículo permite también su publicación en abierto.
  • Dulcinea
    Compruebe si la revista española en la que ha publicado un artículo permite también su publicación en abierto.
  • Recolecta
  • InvestigaM
  • Observatorio I+D+i UPM
  • OpenCourseWare UPM