Climatización de una vivienda unifamiliar mediante aprovechamiento geotérmico

Cueva García-Hirschfeld, Javier de la (2017). Climatización de una vivienda unifamiliar mediante aprovechamiento geotérmico. Thesis (Master thesis), E.T.S.I. de Minas y Energía (UPM).

Description

Title: Climatización de una vivienda unifamiliar mediante aprovechamiento geotérmico
Author/s:
  • Cueva García-Hirschfeld, Javier de la
Contributor/s:
  • Arranz Revenga, Roberto
Item Type: Thesis (Master thesis)
Masters title: Ingeniería de Minas
Date: September 2017
Subjects:
Faculty: E.T.S.I. de Minas y Energía (UPM)
Department: Ingeniería Geológica y Minera
Creative Commons Licenses: Recognition - No derivative works - Non commercial

Full text

[img]
Preview
PDF - Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (11MB) | Preview

Abstract

Este trabajo se trata de un análisis de los procedimientos a seguir para realizar la climatización de una vivienda unifamiliar mediante el aprovechamiento de la energía geotérmica, que es un recurso renovable, gratuito, inagotable y de una disponibilidad incomparable, a pesar de la poca popularidad que tiene en España. Se presentan las normativas que hay que tener en cuenta para la realización de un proyecto de estas características, la definición de las cargas que debe contrarrestar el sistema de climatización y sus cálculos, el método de perforación que debe emplearse, los materiales que se deben emplearlas como la bomba de calor geotérmica que será necesario instalar y un estudio de la iluminación adecuada. Finalmente, se presenta un estudio económico en el que se compara la instalación de este sistema con otro más convencional, obteniéndose el tiempo en el que se amortiza una inversión que es, sin duda, mucho mayor que la convencional. Se concluye, que esta tecnología no es viable para una vivienda unifamiliar de estas characteristicas, siendo más recomendable emplearla en edificios de mayor carga, donde los costes se puedan repartir mejor.This project is an analysis of the procedures to be followed to carry out the climatization of a single family house by means of the use of geothermal energy, which is a renewable resource, free of charge, inexhaustible and has an incomparable availability, despite the use it has in our country. Here it is presented the regulations to be taken into account for the realization of a project of these characteristics, the de_nition of the loads to be countered by the heating and cooling system and its calculations, the drilling method and materials to be used, as well as the geothermal heat pump that will need to be installed and a study of the adequate lighting. Finally, an economic study is presented comparing the installation of this system with a more conventional one, obtaining the recovery time for an investment which is, undoubtedly, much greater than the conventional one. It is concluded that this technology is not viable for a single family house of these characteristics, being more advisable to use it in buildings of greater load, where the costs can be better distributed.

More information

Item ID: 48711
DC Identifier: http://oa.upm.es/48711/
OAI Identifier: oai:oa.upm.es:48711
Deposited by: Biblioteca ETSI Minas y Energía
Deposited on: 11 Dec 2017 12:38
Last Modified: 11 Dec 2017 12:38
  • Logo InvestigaM (UPM)
  • Logo GEOUP4
  • Logo Open Access
  • Open Access
  • Logo Sherpa/Romeo
    Check whether the anglo-saxon journal in which you have published an article allows you to also publish it under open access.
  • Logo Dulcinea
    Check whether the spanish journal in which you have published an article allows you to also publish it under open access.
  • Logo de Recolecta
  • Logo del Observatorio I+D+i UPM
  • Logo de OpenCourseWare UPM