LICOR-Liquid Columns' Resonances

Langbein, D.; Falk, F.; GroBbach, R.; Heide, W.; Bauer, H.; Meseguer Ruiz, José; Perales Perales, José Manuel y Sanz Andres, Angel Pedro (1995). LICOR-Liquid Columns' Resonances. En: "Symposium on Scientific Results of the German Spacelab Mission D-2", 14/03/1994-16/03/1994, Norderney, Germany. ISBN 978-3-89100-025-1.

Descripción

Título: LICOR-Liquid Columns' Resonances
Autor/es:
  • Langbein, D.
  • Falk, F.
  • GroBbach, R.
  • Heide, W.
  • Bauer, H.
  • Meseguer Ruiz, José
  • Perales Perales, José Manuel
  • Sanz Andres, Angel Pedro
Tipo de Documento: Ponencia en Congreso o Jornada (Artículo)
Título del Evento: Symposium on Scientific Results of the German Spacelab Mission D-2
Fechas del Evento: 14/03/1994-16/03/1994
Lugar del Evento: Norderney, Germany
Título del Libro: Proceedings of the Norderney Symposium on Scientific Results of the German Spacelab Mission D-2
Fecha: 1995
ISBN: 978-3-89100-025-1
Materias:
Escuela: E.T.S.I. Aeronáuticos (UPM) [antigua denominación]
Departamento: Vehículos Aeroespaciales [hasta 2014]
Licencias Creative Commons: Reconocimiento - Sin obra derivada - No comercial

Texto completo

[img]
Vista Previa
PDF (Document Portable Format) - Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (389kB) | Vista Previa

Resumen

The aim of the experiment LICOR was the investigation of the axial resonances oi cylindrical liquid columns supported by equal circular coaxiaJ disks. In preparation ot the D-2 experiment a •heoreiical model has been developed, which exactly describes the small amplitude oscillations of finite cylindrical columns between coaxial circular disks. In addition, in terrestrial experiments the resonance frequencies of small liquid columns with up to 5 mm in diameter have been determined and investigations with density-matched liquids (silicon oil in a waierlmethanol mixture) have been performed. For the D-2 experiment LICOR the front disk and the rear disk lor use in the AFPM have been constructed and equipped with pressure sensors and the necessary electronics. The pressure exerted by the oscillating liquid column on trie supporting disks vsas as low as 10 Pa. Since the data downlink of the Materials Research Laboratory was just one signal oer second and channel, it was necessary to determine amplitude and phase of the pressure already in the LICOR disks. The D-2 experiment has been successfully performed. It has fully confirmed the theoretical models and remarkably supplements the experiments on small liquid columns and on density-matched columns.

Más información

ID de Registro: 4991
Identificador DC: http://oa.upm.es/4991/
Identificador OAI: oai:oa.upm.es:4991
Depositado por: Memoria Investigacion
Depositado el: 16 Nov 2010 11:29
Ultima Modificación: 20 Abr 2016 13:59
  • Open Access
  • Open Access
  • Sherpa-Romeo
    Compruebe si la revista anglosajona en la que ha publicado un artículo permite también su publicación en abierto.
  • Dulcinea
    Compruebe si la revista española en la que ha publicado un artículo permite también su publicación en abierto.
  • Recolecta
  • e-ciencia
  • Observatorio I+D+i UPM
  • OpenCourseWare UPM