Interrelación de la arquitectura bioclimática vinculada al ETFE

Escaned Canalís, Carmen (2018). Interrelación de la arquitectura bioclimática vinculada al ETFE. Proyecto Fin de Carrera / Trabajo Fin de Grado, E.T.S. Arquitectura (UPM).

Description

Title: Interrelación de la arquitectura bioclimática vinculada al ETFE
Author/s:
  • Escaned Canalís, Carmen
Contributor/s:
  • García Santos, Alfonso
Item Type: Final Project
Degree: Grado en Fundamentos de la Arquitectura
Date: June 2018
Subjects:
Faculty: E.T.S. Arquitectura (UPM)
Department: Construcción y Tecnología Arquitectónica
Creative Commons Licenses: Recognition - No derivative works - Non commercial

Full text

[img]
Preview
PDF - Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (5MB) | Preview

Abstract

El presente trabajo tiene como objeto interrelacionar el copolímero etilenotetrefluoretileno, desde un punto de vista constructivo con aspectos bioclimáticos pasivos, y en sus envolventes. En primer lugar, se ha realizado una investigación detallada sobre el plástico para obtener unas conclusiones constructivas, sobre del material, elemento, unidad constructiva y sistema constructivo. Para detectar los sistemas bioclimáticos pasivos, había que tener en cuenta las condiciones climáticas. Una vez estudiadas, se procede a fijar unos criterios en cuanto al diseño de la envolvente. Mediante el estudio de los cuatro casos de estudio y analizándolos con los criterios planteados en los anteriores capítulos, se obtiene una tabla pictográfica en la que se pueden comparar los edificios y llegar a conclusiones fundamentadas y poder plantear las respectiva envolvente. The purpose of this work is to interrelate the ethylene tetrafluoroethylene copolymer, from a constructive point of view with passive bioclimatic aspects, and in its enclosures. In the first place, a detailed investigation on this plastic has been carried out with the aim of obtaining conclusions about the material, element, constructive unit and constructive system. Climatic conditions had to be taken into account to detect passive bioclimatic systems. Once studied, we proceed to set some criteria regarding the design of the envelope. By studying these four cases and analyzing them with the criteria set out in the previous chapters, a pictographic table is obtained in which the buildings can be compared and conclusions reached and the respective enclosures posited.

More information

Item ID: 51758
DC Identifier: http://oa.upm.es/51758/
OAI Identifier: oai:oa.upm.es:51758
Deposited by: Biblioteca ETS Arquitectura
Deposited on: 27 Jul 2018 06:30
Last Modified: 27 Jul 2018 06:30
  • Logo InvestigaM (UPM)
  • Logo GEOUP4
  • Logo Open Access
  • Open Access
  • Logo Sherpa/Romeo
    Check whether the anglo-saxon journal in which you have published an article allows you to also publish it under open access.
  • Logo Dulcinea
    Check whether the spanish journal in which you have published an article allows you to also publish it under open access.
  • Logo de Recolecta
  • Logo del Observatorio I+D+i UPM
  • Logo de OpenCourseWare UPM