Proyecto de rehabilitación energética. Edificio oficinas de Gas Natural Fenosa

Vega Sánchez, José Antonio (2019). Proyecto de rehabilitación energética. Edificio oficinas de Gas Natural Fenosa. Thesis (Master thesis), E.T.S.I. de Minas y Energía (UPM).

Description

Title: Proyecto de rehabilitación energética. Edificio oficinas de Gas Natural Fenosa
Author/s:
  • Vega Sánchez, José Antonio
Contributor/s:
  • López Peón, Juan Francisco
Item Type: Thesis (Master thesis)
Masters title: Eficiencia Energética en la Edificación, la Industria y el Transporte
Date: June 2019
Subjects:
Faculty: E.T.S.I. de Minas y Energía (UPM)
Department: Ingeniería Mecánica, Química y Diseño Industrial
Creative Commons Licenses: Recognition - No derivative works - Non commercial

Full text

[img]
Preview
PDF - Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (6MB) | Preview

Abstract

El desgaste/deterioro de la capa de O₃ (Ozono), que nos protege de la radiación ultravioleta que está calentando el planeta tierra y llevándolo a su autodestrucción, es producido por los gases de efecto invernadero (GEI)2 que emite la sociedad en sus actividades diarias. Este efecto se conoce como Efecto Invernadero. Los edificios, el sector industrial y el sector transporte son los principales causantes de los gases contaminantes. La sociedad a nivel mundial está intentando reducir sus emisiones con diferentes tratados internacionales, en los que se implementan líneas de actuación y de obligado cumplimiento para reducirlos y hacer una sociedad más sostenible. En este estudio nos vamos a centrar en los edificios, responsables según estudios recientes del 30% de las emisiones globales. Para ello nos vamos a basar en la normativa vigente en España, CTE (Código Técnico de la Edificación) y RITE (Reglamento de Instalaciones Térmicas en los Edificios) y vamos a utilizar el simulador energético de Edificios HULC(Herramienta unificada Lider-Calener) y el Postcalener para lectura de resultados. Con los resultados del simulador seremos capaces de determinar dónde podemos implementar mejoras en la piel exterior del edificio, aumentando su aislamiento con nuevos materiales y reduciendo la transmisión de energía, y también seremos capaces de analizarlos consumos de las instalaciones, y de este modo poder proponer mejoras que reduzcan el consumo energético del edificio. El objetivo que persigue la sociedad y que tratamos de conseguir en este trabajo es un ¨Edificio Energía Cero (EEC)¨, es decir, un edificio muy bien aislado con un consumo muy bajo, y que a su vez sea capaz de autogenerar esa energía que necesita para tener un confort interior óptimo. The deterioration of the Ozone layer, which protects us from the ultraviolet radiation that isheating the planet earth and leading to its self-destruction, is produced by the greenhousegases that society emits in its daily activities.Buildings, the industrial sector and the transport sector are the main causes of these polluting gases. The international community is trying to reduce its emissions with different international treaties, in which lines of action and mandatory compliance are implemented to reduce themand make society more sustainable.In this study we see ourselves focusing on buildings, responsible according to recent studiesfor 30% of global emissions. To do this we are going to use the current regulations in Spain,CTE (Technical Building Code) and RITE (Regulation of Thermal Installations in Buildings) andwe will use the energy simulator of Buildings HULC (Unified Tool Lider-Calener).With the results of the simulator we will be able to determine where we can implement improvements in the exterior skin of the building, increasing its isolation with new materials,and we will also be able to analyze the consumption of the thermal installations, and in this way we can propose improvements that will reduce the energy consumption of the building.The goal pursued by society and that we try to achieve in this work is a "Energy Zero" building,that is, a very well-insulated building with very low consumption, and that in turn is capable ofgenerating the energy it needs to have an optimal interior comfort.

More information

Item ID: 57281
DC Identifier: http://oa.upm.es/57281/
OAI Identifier: oai:oa.upm.es:57281
Deposited by: Biblioteca ETSI Minas y Energía
Deposited on: 14 Nov 2019 11:36
Last Modified: 01 Apr 2020 22:30
  • Logo InvestigaM (UPM)
  • Logo GEOUP4
  • Logo Open Access
  • Open Access
  • Logo Sherpa/Romeo
    Check whether the anglo-saxon journal in which you have published an article allows you to also publish it under open access.
  • Logo Dulcinea
    Check whether the spanish journal in which you have published an article allows you to also publish it under open access.
  • Logo de Recolecta
  • Logo del Observatorio I+D+i UPM
  • Logo de OpenCourseWare UPM