Performance analysis of present cup anemometers

Ramos Cenzano, Álvaro and Ogueta Gutierrez, Mikel and Pindado Carrion, Santiago (2019). Performance analysis of present cup anemometers. "Journal of Energy Systems", v. 3 (n. 4); pp. 129-138. ISSN 2602-2052. https://doi.org/10.30521/jes.614212.

Description

Title: Performance analysis of present cup anemometers
Author/s:
  • Ramos Cenzano, Álvaro
  • Ogueta Gutierrez, Mikel
  • Pindado Carrion, Santiago
Item Type: Article
Título de Revista/Publicación: Journal of Energy Systems
Date: 2019
ISSN: 2602-2052
Volume: 3
Subjects:
Freetext Keywords: Accuracy, Calibration, Cup anemometer, MEASNET, Wind speed sensor
Faculty: Instituto de Microgravedad Ignacio Da Riva (UPM)
Department: Sistemas Aeroespaciales, Transporte Aéreo y Aeropuertos
UPM's Research Group: Desarrollo y Ensayos Aeroespaciales DEA
Creative Commons Licenses: Recognition - No derivative works - Non commercial

Full text

[img] PDF - Users in campus UPM only - Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (1MB)

Abstract

The cup anemometer, wind speed sensor developed by T.R. Robinson in the 19th century, remains today as the best option in relation to important scientific and economic sectors such as the meteorology sector or the wind energy sector. Despite the great advances reached by new technologies as sonic anemometry, LIDAR or SODAR, the cup anemometer is the most demanded wind speed sensor thanks to its balance between the accuracy, reliability, endurance and the cost. In the present paper, the work carried out in relation to this instrument at the IDR/UPM Institute is briefly summarized, and then the results from the last research testing campaigns are included. The output signal of the first class cup anemometers such as Thies CLIMA First Class, Thies CLIMA 4.3350, and Vector Instruments is analyzed to obtain insights on the instrument accuracy. It is found that three accelerations of the rotor are converted into a pulsed output signals, leading to some error if that is not taken into account. Besides, the way the output signal is registered in order to correlate the output frequency with the wind speed has proven to be also a source of error. Two ways of extracting the output frequency, namely by Counting Pulses (CP), and by using FFT are compared. Results indicate that the wind speed errors are six times larger in the case of using FFT.

More information

Item ID: 57564
DC Identifier: http://oa.upm.es/57564/
OAI Identifier: oai:oa.upm.es:57564
DOI: 10.30521/jes.614212
Official URL: https://dergipark.org.tr/en/download/article-file/868125
Deposited by: Biblioteca ETSI Aeronauticos
Deposited on: 10 Jan 2020 07:37
Last Modified: 22 Jan 2020 07:29
  • Logo InvestigaM (UPM)
  • Logo GEOUP4
  • Logo Open Access
  • Open Access
  • Logo Sherpa/Romeo
    Check whether the anglo-saxon journal in which you have published an article allows you to also publish it under open access.
  • Logo Dulcinea
    Check whether the spanish journal in which you have published an article allows you to also publish it under open access.
  • Logo de Recolecta
  • Logo del Observatorio I+D+i UPM
  • Logo de OpenCourseWare UPM