Influence on the Electromagnetic Compatibility of the Configuration of the Neutral in Grounding Systems for Hospitals

Domínguez González-Seco, Esteban and Gómez Pulido, José M. and Garces Jiménez, Alberto and Gómez Gómez, David (2019). Influence on the Electromagnetic Compatibility of the Configuration of the Neutral in Grounding Systems for Hospitals. "Revista Ibérica de Sistemas y Tecnologías de la Información (RISTI)", v. E23 ; pp. 417-429. ISSN 1646-9895.

Description

Title: Influence on the Electromagnetic Compatibility of the Configuration of the Neutral in Grounding Systems for Hospitals
Author/s:
  • Domínguez González-Seco, Esteban
  • Gómez Pulido, José M.
  • Garces Jiménez, Alberto
  • Gómez Gómez, David
Item Type: Article
Título de Revista/Publicación: Revista Ibérica de Sistemas y Tecnologías de la Información (RISTI)
Date: October 2019
ISSN: 1646-9895
Volume: E23
Subjects:
Freetext Keywords: Grounding System; Neutral Conductor; Electromagnetic Compatibility; Electromagnetic Interference; Hospital
Faculty: E.T.S. Arquitectura (UPM)
Department: Construcción y Tecnología Arquitectónica
Creative Commons Licenses: Recognition - No derivative works - Non commercial

Full text

[img]
Preview
PDF - Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (1MB) | Preview

Abstract

This research analyzes the impact in the electromagnetic compatibility that the configurations of the neutral of grounding systems have in hospitals. The results herein propose a consistent standard model as the basis for future regulations to provide consistent guidelines for designing the power and telecommunications networks in hospitals, reducing the undesirable low frequency radiation exposure and improving their operations and maintenance. An experiment was carried out in two hospitals with different neutral configurations, so that the comparison could be validated. The outcomes of the simulation are presented and discussed, checking their compliance with International Electromagnetic Compatibility Normative. The TN-S neutral configuration is compared with the current standard design recommendations, showing a better performance in terms of network stability and electromagnetic compatibility. This study tries to justify the implementation of a design practice for the grounding system of hospitals which improves the management of the installation, its safety and durability.

More information

Item ID: 57906
DC Identifier: http://oa.upm.es/57906/
OAI Identifier: oai:oa.upm.es:57906
Official URL: http://www.risti.xyz/index.php?option=com_content&view=article&id=32&Itemid=131&lang=es
Deposited by: Memoria Investigacion
Deposited on: 13 Feb 2020 11:39
Last Modified: 13 Feb 2020 11:39
  • Logo InvestigaM (UPM)
  • Logo GEOUP4
  • Logo Open Access
  • Open Access
  • Logo Sherpa/Romeo
    Check whether the anglo-saxon journal in which you have published an article allows you to also publish it under open access.
  • Logo Dulcinea
    Check whether the spanish journal in which you have published an article allows you to also publish it under open access.
  • Logo de Recolecta
  • Logo del Observatorio I+D+i UPM
  • Logo de OpenCourseWare UPM