Characterization of Fresnel-Köhler Concentrator

Cvetkovic, Aleksandra and Mohedano del Pozo, Raúl and Zamora Herranz, Pablo and Benitez Gimenez, Pablo and Miñano Dominguez, Juan Carlos and Chaves, Julio and Hernández Sanz, Maikel and Vilaplana, J. (2010) Characterization of Fresnel-Köhler Concentrator. In: 25th European Photovoltaic Solar Energy Conference and Exhibition / 5th World Conference on Photovoltaic Energy Conversion, 06/09/2010 - 10/09/2010, Valencia, Spain.

Ver estadisticas de descargas para este eprint (solo desde ordenadores de la UPM) Estadisticas UPM
Bookmark and Share
Item Type:Presentation at Congress or Day (Article)
Authors/Creators:
Creators NameCreators email (if known)
Cvetkovic, Aleksandra
Mohedano del Pozo, Raúl
Zamora Herranz, Pablo
Benitez Gimenez, Pablo
Miñano Dominguez, Juan Carlos
Chaves, Julio
Hernández Sanz, Maikel
Vilaplana, J.
Title:Characterization of Fresnel-Köhler Concentrator
Event Title:25th European Photovoltaic Solar Energy Conference and Exhibition / 5th World Conference on Photovoltaic Energy Conversion
Event Dates:06/09/2010 - 10/09/2010
Event Location:Valencia, Spain
Title of Book:Proceedings of the 25th European Photovoltaic Solar Energy Conference and Exhibition / 5th World Conference on Photovoltaic Energy Conversion
Publisher:European Photovoltaic Solar Energy Conference and Exhibition (EU PVSEC)
Date:2010
ISBN:3-936338-26-4
Department:Physical Electronics
Faculty:E.T.S.I. Telecommunication (UPM)
Creative Commons licenses:Recognition - No derivative works - No commercial
Item ID:7528
Subjects:Renewable Energy

Texto completo disponible como:

[img]
Preview
PDF
498Kb - Idioma: English

Official URL: http://www.eupvsec-proceedings.com/proceedings?paper=9372

Abstract

Getting a lower energy cost has always been a challenge for concentrated photovoltaic. The FK concentrator enhances the performance (efficiency, acceptance angle and manufacturing tolerances) of the conventional CPV system based on a Fresnel primary stage and a secondary lens, while keeping its simplicity and potentially low-cost manufacturing. This work presents some measured performance features of a FK prototype that show its skills and potential for the achievement of competitive electricity generation costs. First prototype was built and characterized, and efficiency higher than 30% has been demonstrated