Alonso Alonso, Maria Cruz y Sanchez, M. (2010). Repasivation of steel rebars after and electrochemical chlorides removal treatment by simultaneous application of calcium nitrite. En: "6th international conference on concrete under severe conditions (CONSEC '10)", 07/06/2010 - 09/06/2010, Mérida, Yucatán, Méjico. ISBN 9780415593168.

Descripción

Título: Repasivation of steel rebars after and electrochemical chlorides removal treatment by simultaneous application of calcium nitrite
Autor/es:
  • Alonso Alonso, Maria Cruz
  • Sanchez, M.
Tipo de Documento: Ponencia en Congreso o Jornada (Sin especificar)
Título del Evento: 6th international conference on concrete under severe conditions (CONSEC '10)
Fechas del Evento: 07/06/2010 - 09/06/2010
Lugar del Evento: Mérida, Yucatán, Méjico
Título del Libro: Proceedings of the 6th international conference on concrete under severe conditions (CONSEC '10)
Fecha: 2010
ISBN: 9780415593168
Materias:
Escuela: Centro de Seguridad y Durabilidad Estructural de Materiales (CISDEM) (UPM)
Departamento: Otro
Licencias Creative Commons: Reconocimiento - Sin obra derivada - No comercial

Texto completo

[img]
Vista Previa
PDF (Document Portable Format) - Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (200kB) | Vista Previa

Resumen

The Electrochemical Removal of Chlorides (CE) can be proposed as methodology for the treatment of reinforced concrete structures affected by corrosion. This methodology is based on the temporary application of an external voltage between an external anode located on the concrete and the rebar connected as cathode. After the treatment, the extraction of chloride from the concrete level and the repassivation of the rebar are expected. The migration of ionic inhibitors to the rebar could be considered during the connection of an electric field to favour the regeneration of the passive film. In present work a novel methodology is proposed to enhance the efficiency of an Electrochemical Chloride Extraction treatment by simultaneous application of calcium nitrite. A fast repassivation of the rebar is reached after the CE treatment when the inhibitor is applied during the electric field connection. The penetration of the inhibitor near the rebar surface has been confirmed by. The new passive conditions of the steel rebar after the treatment were confirmed by electrochemical measurements. The penetration of the inhibitor near the rebar surface was assured by analysing of nitrite dissolved into the aqueous phase. The presence of nitrite promoted a faster regeneration of the passive film that is maintained in time.

Más información

ID de Registro: 9341
Identificador DC: http://oa.upm.es/9341/
Identificador OAI: oai:oa.upm.es:9341
Depositado por: Memoria Investigacion
Depositado el: 24 Oct 2011 08:30
Ultima Modificación: 20 Abr 2016 17:48
  • Open Access
  • Open Access
  • Sherpa-Romeo
    Compruebe si la revista anglosajona en la que ha publicado un artículo permite también su publicación en abierto.
  • Dulcinea
    Compruebe si la revista española en la que ha publicado un artículo permite también su publicación en abierto.
  • Recolecta
  • e-ciencia
  • Observatorio I+D+i UPM
  • OpenCourseWare UPM