A computationally efficient reduced order model to generate multi-parameter fluid-thermal databases

Bache, E.; Alonso Fernández, Diego; Velázquez López, Ángel Gerardo y Vega de Prada, José Manuel (2012). A computationally efficient reduced order model to generate multi-parameter fluid-thermal databases. "International journal of thermal sciences", v. 52 ; pp. 145-153. ISSN 1290-0729. https://doi.org/10.1016/j.ijthermalsci.2011.08.022.

Descripción

Título: A computationally efficient reduced order model to generate multi-parameter fluid-thermal databases
Autor/es:
  • Bache, E.
  • Alonso Fernández, Diego
  • Velázquez López, Ángel Gerardo
  • Vega de Prada, José Manuel
Tipo de Documento: Artículo
Título de Revista/Publicación: International journal of thermal sciences
Fecha: Febrero 2012
Volumen: 52
Materias:
Escuela: E.T.S.I. Aeronáuticos (UPM) [antigua denominación]
Departamento: Fundamentos Matemáticos de la Tecnología Aeronáutica [hasta 2014]
Licencias Creative Commons: Reconocimiento - Sin obra derivada - No comercial

Texto completo

[img]
Vista Previa
PDF (Document Portable Format) - Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (382kB) | Vista Previa

Resumen

A reduced order model (ROM) is proposed to generate multi-parameter databases of some fluid-thermal problems, using a combination of proper orthogonal decomposition, a gradient-like method, and a continuation method. The resulting ROM greatly reduces the CPU time required by slower methods based on genetic algorithm formulations. As a byproduct, the number of required snapshots is also reduced, which yields an additional improvement of the computational efficiency. The work presented in this article aims to facilitate the use of ROMs in industrial environments, in which time is a very important asset. The methodology is illustrated with the non-isothermal flow past a backward-facing step in the laminar regime, which is a representative problem, related to the engineering design of micro-heat sinks.

Más información

ID de Registro: 9447
Identificador DC: http://oa.upm.es/9447/
Identificador OAI: oai:oa.upm.es:9447
Identificador DOI: 10.1016/j.ijthermalsci.2011.08.022
URL Oficial: http://www.sciencedirect.com/science/article/pii/S1290072911002602
Depositado por: Memoria Investigacion
Depositado el: 12 Mar 2013 11:23
Ultima Modificación: 20 Abr 2016 17:51
  • Open Access
  • Open Access
  • Sherpa-Romeo
    Compruebe si la revista anglosajona en la que ha publicado un artículo permite también su publicación en abierto.
  • Dulcinea
    Compruebe si la revista española en la que ha publicado un artículo permite también su publicación en abierto.
  • Recolecta
  • e-ciencia
  • Observatorio I+D+i UPM
  • OpenCourseWare UPM