RT Journal Article SR 00 ID 10.1016/j.corsci.2011.05.023 A1 Sanz Recio, Javier A1 Alonso Alonso, Maria Cruz A1 Gaillet, L. A1 Sanchez Oreja, Maria Elena T1 Hydrogen embrittlement risk of high strength galvanized steel in contact with alkaline media JF Corrosion Science YR 2011 FD 2011 VO 53 SP 2853 OP 2860 K1 A. Steel reinforced concrete; A. Zinc; C. Hydrogenembrittlement AB The critical conditions for hydrogenembrittlement (HE) risk of highstrengthgalvanizedsteel (HSGS) wires and tendons exposed to alkaline concrete pore solutions have been evaluated by means of electrochemical and mechanical testing. There is a relationship between the hydrogenembrittlementrisk in HSGS and the length of hydrogen evolution process in alkalinemedia. The galvanizedsteel suffers anodic dissolution simultaneously to the hydrogen evolution which does not stop until the passivation process is completed. HSGS wires exposed to a very highalkalinemedia have showed HE risk with loss in mechanical properties only if long periods with hydrogen evolution process take place with a simultaneous intensive galvanized coating reduction. PB Elsevier B.V. SN 0010-938X LK http://oa.upm.es/12300/