eprintid: 41680 rev_number: 16 eprint_status: archive userid: 1903 dir: disk0/00/04/16/80 datestamp: 2017-05-03 12:39:02 lastmod: 2017-05-03 12:48:50 status_changed: 2017-05-03 12:48:50 type: book_section metadata_visibility: show creators_name: González Rodrigo, Sonsoles creators_name: Cobo Escamilla, Alfonso creators_name: González Yunta, Francisco creators_id: sonsoles.gonzalez@upm.es creators_id: alfonso.cobo@upm.es creators_id: francisco.gonzalez.yunta@upm.es title: Análisis del comportamiento a arrancamiento de anclajes de seguridad para andamios en fábricas reales de ladrillo perforado publisher: [s.n.] rights: by-nc-nd ispublished: pub subjects: construccion full_text_status: public abstract: Existen numerosos trabajos de investigación que analizan el comportamiento y la resistencia de anclajes de acero en elementos de hormigón armado. Sin embargo es habitual en obras de rehabilitación, encontrarse con la necesidad de levantar una estructura de andamio necesariamente anclada al muro de fábrica que constituye la fachada. El cumplimiento de la actual normativa española para el cálculo de andamios supone la consideración de la acción del viento que incide en las lonas de protección de estas estructuras. Éste efecto puede someter a los elementos de anclaje en fachada a un esfuerzo de arrancamiento. El presente trabajo analiza el comportamiento de anclajes de acero tipo cáncamo, insertados en tacos de plástico y con distintas longitudes de entrega dentro del muro real de fábrica de ladrillo. Para ello se ha seguido el método de ensayo expuesto en las directrices europeas para anclajes de plástico con distintos usos en fábricas de ladrillo para uso no estructural (EOTA-ETAG-20). ABSTRACT: Strength and performance of steel anchorages in reinforced concrete elements have greatly been analyzed in research works. Nevertheless, quite commonly, there is a need to build up a scaffolding structure anchored to the masonry wall forming the facade. In order to meet the present in force regulation on Spain when designing the scaffolding, the wind action over the protective canvas has to be taken into consideration. This effect can generate on the facade wall fixings a strong pullout stress. This paper analyzes the behavior of steel anchorages inserted into plastic plugs with different lengths, in real masonry walls. To this end, testing methods shown in European guidelines for plastic anchorages for multiple uses in masonry for non-structural applications (EOTA-ETAG-20) have been followed. date_type: published date: 2015 place_of_pub: [S.l.] pagerange: 81-89 pages: 142 event_title: Analisis del comportamiento a arrancamiento de anclajes de seguridad event_location: Madrid institution: Edificacion department: Construcciones refereed: TRUE isbn: 978-84-608-3831-9 book_title: Nuevos avances en materiales, técnicas y sistemas de edificación citation: González Rodrigo, Sonsoles and Cobo Escamilla, Alfonso and González Yunta, Francisco (2015). Análisis del comportamiento a arrancamiento de anclajes de seguridad para andamios en fábricas reales de ladrillo perforado. In: "Nuevos avances en materiales, técnicas y sistemas de edificación". [s.n.], [S.l.], pp. 81-89. ISBN 978-84-608-3831-9. document_url: http://oa.upm.es/41680/7/INVE_MEM_2014_218139.pdf