Bustamante Montoro, Rosa and Lauret Aguirregabiria, Benito and Monjo Carrió, Juan and Valero, J.M. (2006). Preliminary Study and Proposal for Restoring a Jesuit College at Saragossa, Spain. In: "5th International Conference Structural Analysis of Historical Constructions. Possibilities of numerical and experimental techniques", 06/11/2006 - 08/11/2006, New Delhi, India. ISBN 1403-93155-0; 978-1403-93155-9.
Title: | Preliminary Study and Proposal for Restoring a Jesuit College at Saragossa, Spain |
---|---|
Author/s: |
|
Item Type: | Presentation at Congress or Conference (Article) |
Event Title: | 5th International Conference Structural Analysis of Historical Constructions. Possibilities of numerical and experimental techniques |
Event Dates: | 06/11/2006 - 08/11/2006 |
Event Location: | New Delhi, India |
Title of Book: | Proceedings of 5th International Conference Structural Analysis of Historical Constructions. Possibilities of numerical and experimental techniques |
Date: | 8 November 2006 |
ISBN: | 1403-93155-0; 978-1403-93155-9 |
Volume: | 1 |
Subjects: | |
Freetext Keywords: | Jesuit church, interior lighting |
Faculty: | E.T.S. Arquitectura (UPM) |
Department: | Construcción y Tecnología Arquitectónica |
UPM's Research Group: | Analisis e Intervencion en el Patrimonio Arquitectonico(AIPA) |
Creative Commons Licenses: | Recognition - Non commercial - Share |
|
PDF
- Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (982kB) | Preview |
A historical study and a construction pathology survey were conducted prior to proposing a solution for restoring the upper windows on the south side of Old San Carlos College at Saragossa (16th-17th centuries), wich had been forteited to add a third storey to the cloister. Althought initially designed to a simple large hall format, the church is a harmonius blend of Aragonese Gothic architecture and typical Jesuit scheme, consisting in a central nave flanket by chapel-confessional and raised galleries for the community. A subsequent enlargement of the roof, wich rests on the original framing over the central nave, reduced the mechanical strength of the principal rafters on the opposite side, prompting a concomitant imbalance of forces that has affected the entire structure. In view of the foregoing, in addition to restituting the upper window, the proposal solution envisages restoring the roof over the central nave to its original design, and with the interior lighting in the church.