Review of the Performance of Residential PV systems in Belgium

Leloux, Jonathan, Narvarte Fernández, Luis and Trebosc, David (2011). Review of the Performance of Residential PV systems in Belgium. "Renewable and Sustainable Energy Reviews", v. 16 (n. 1); pp. 178-184. ISSN 1364-0321. https://doi.org/10.1016/j.rser.2011.07.145.

Description

Title: Review of the Performance of Residential PV systems in Belgium
Author/s:
  • Leloux, Jonathan
  • Narvarte Fernández, Luis
  • Trebosc, David
Item Type: Article
Título de Revista/Publicación: Renewable and Sustainable Energy Reviews
Date: 2011
ISSN: 1364-0321
Volume: 16
Subjects:
Freetext Keywords: Residencial sistema PV; La producción de energía; Coeficiente de rendimiento; Rendimiento del índice; PI; Bélgica
Faculty: E.U.I.T. Telecomunicación (UPM)
Department: Ingeniería de Circuitos y Sistemas [hasta 2014]
Creative Commons Licenses: Recognition - No derivative works - Non commercial

Full text

[thumbnail of INVE_MEM_2011_106710.pdf]
Preview
PDF - Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (2MB) | Preview

Abstract

The main objective of this paper is to review the state of the art of residential PV systems in Belgium by the analysis of the operational data of 993 installations. For that, three main questions are posed: how much energy do they produce? What level of performance is associated to their production? Which are the key parameters that most influence their quality? This work brings answers to these questions. A middling commercial PV system, optimally oriented, produces a mean annual energy of 892 kWh/kWp. As a whole, the orientation of PV generators causes energy productions to be some 6% inferior to optimally oriented PV systems. The mean performance ratio is 78% and the mean performance index is 85%. That is to say, the energy produced by a typical PV system in Belgium is 15% inferior to the energy produced by a very high quality PV system. Finally, on average, the real power of the PV modules falls 5% below its corresponding nominal power announced on the manufacturer's datasheet. Differences between real and nominal power of up to 16% have been detected.

More information

Item ID: 11708
DC Identifier: https://oa.upm.es/11708/
OAI Identifier: oai:oa.upm.es:11708
DOI: 10.1016/j.rser.2011.07.145
Official URL: http://www.sciencedirect.com/science/article/pii/S...
Deposited by: Memoria Investigacion
Deposited on: 20 Nov 2012 13:33
Last Modified: 19 May 2017 12:30
  • Logo InvestigaM (UPM)
  • Logo GEOUP4
  • Logo Open Access
  • Open Access
  • Logo Sherpa/Romeo
    Check whether the anglo-saxon journal in which you have published an article allows you to also publish it under open access.
  • Logo Dulcinea
    Check whether the spanish journal in which you have published an article allows you to also publish it under open access.
  • Logo de Recolecta
  • Logo del Observatorio I+D+i UPM
  • Logo de OpenCourseWare UPM