Amplificador de señal analógico basado en conceptos biomiméticos. Desarrollo de modelos computacionales y validación experimental

Guadalupe Suarez, Viana Lida (2012). Amplificador de señal analógico basado en conceptos biomiméticos. Desarrollo de modelos computacionales y validación experimental. Thesis (Doctoral), E.T.S.I. Industriales (UPM). https://doi.org/10.20868/UPM.thesis.14687.

Description

Title: Amplificador de señal analógico basado en conceptos biomiméticos. Desarrollo de modelos computacionales y validación experimental
Author/s:
  • Guadalupe Suarez, Viana Lida
Contributor/s:
  • Recuero López, Manuel
  • Militello Militello, Carmelo
Item Type: Thesis (Doctoral)
Read date: 2012
Subjects:
Faculty: E.T.S.I. Industriales (UPM)
Department: Ingeniería Mecánica y de Fabricación [hasta 2014]
Creative Commons Licenses: Recognition - No derivative works - Non commercial

Full text

[thumbnail of VIANA_LIDIA_GUADALUPE_SUAREZ.pdf]
Preview
PDF - Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (5MB) | Preview

Abstract

La presente tesis doctoral estudia las características de un transductor acústico bioinspirado en la estructura del maxilar inferior de un Zifio de Couvier (Ziphius cavirostris). El mecanismo de funcionamiento del sensor se basa en las características de un sistema acoplado formado por los distintos componentes acústicos identificados en el maxilar. Para analizar las características del sensor se propone un modelo simplificado 2D que consta de una cavidad cerrada con forma de bocina acoplada a una lengüeta. Una parte de la lengüeta se encuentra dentro de la cavidad y otra en el exterior. Dicha lengüeta detecta los cambios de presión acústica y las vibraciones generadas por el sonido y las transmite con ondas de flexión al interior de la cavidad. La excitación prolongada sobre la placa puede provocar la activación de los modos propios del sistema acoplado. Dichos modos se caracterizan porque presentan un máximo de presión en el cono de la bocina la cual a su vez actúa como un amplificador acústico. Mediante el Método de los elementos Finitos se analizan las características acústicas del sensor y se construye un prototipo experimental para validar los resultados evaluados en el modelo numérico. Se propone una metodología numérica que permite desarrollar y validar un elemento tetraédrico para caracterizar el comportamiento isotrópico de los medios porosos. La metodología permite construir elementos de línea y bidimensionales. A partir de esta metodología se desarrolla un elemento plano ortotrópico. Se realiza un modelo de la cavidad en el que una de las paredes de la bocina está constituida por material poroso y se une la parte exterior de la lengüeta a dicho material para que constituya una viga sobre un apoyo elástico. Se calcula la respuesta modal y se discuten los efectos del material poroso en la eficiencia del transductor y las posibles mejoras a introducir en el mismo. SUMMARY This Thesis studies the characteristics of an acoustic transducer bioinspired by the structure of the lower maxilla of an odontoceto. In this case a Cuvier’s beaked whale (Ziphius cavirostris). The transducer working mechanism is based in a coupled system, with components identified in the maxilla. To analyze the transducer a simplified 2D model composed by a horn shaped closed cavity is modeled. The cavity is coupled with a flat belt. The belt has one part inside the cavity and the other part outside of it. The belt traverses the cavity wall and it is in charge to pick the vibrations from outside and introduce it inside the cavity. The transmission is obtained through the belt bending. A sustained external load with the right frequency contents will allow the system to reach a stationary pressure intensity distribution inside the cavity. Frequencies with modal shapes that show an important intensity increase at the horn tip are of special interest because of the signal amplification. A finite element model is constructed to study the transducer coupled modes and a prototype is constructed to validate the numerical results. A numerical methodology to construct and validate a tetrahedral finite element for isotropic porous materials is presented. The methodology allows constructing linear and 2D elements. It is extended to model orthotropic porous materials behavior. At the end, one of the horn walls is made of an orthotropic material and the external belt is glued to it in order to configure a belt over an elastic foundation. Modal response is evaluated and the porous material effects in the transducer efficiency and further improvements are discussed.

More information

Item ID: 14687
DC Identifier: https://oa.upm.es/14687/
OAI Identifier: oai:oa.upm.es:14687
DOI: 10.20868/UPM.thesis.14687
Deposited by: Archivo Digital UPM 2
Deposited on: 31 Mar 2013 08:06
Last Modified: 10 Oct 2022 10:37
  • Logo InvestigaM (UPM)
  • Logo GEOUP4
  • Logo Open Access
  • Open Access
  • Logo Sherpa/Romeo
    Check whether the anglo-saxon journal in which you have published an article allows you to also publish it under open access.
  • Logo Dulcinea
    Check whether the spanish journal in which you have published an article allows you to also publish it under open access.
  • Logo de Recolecta
  • Logo del Observatorio I+D+i UPM
  • Logo de OpenCourseWare UPM