Application of active heat pulse method with fiber optic temperature sensing for estimation of wetting bulbs and water distribution in drip emitters.

Gil Rodríguez, María ORCID: https://orcid.org/0000-0002-4222-6433, Rodríguez Sinobas, Leonor ORCID: https://orcid.org/0000-0001-9684-6884, Benitez Buelga, Javier and Sánchez Calvo, Raúl ORCID: https://orcid.org/0000-0003-3147-5108 (2013). Application of active heat pulse method with fiber optic temperature sensing for estimation of wetting bulbs and water distribution in drip emitters.. "Agricultural Water Management", v. 120 ; pp. 72-78. ISSN 0378-3774. https://doi.org/10.1016/j.agwat.2012.10.012.

Description

Title: Application of active heat pulse method with fiber optic temperature sensing for estimation of wetting bulbs and water distribution in drip emitters.
Author/s:
Item Type: Article
Título de Revista/Publicación: Agricultural Water Management
Date: 31 March 2013
ISSN: 0378-3774
Volume: 120
Subjects:
Faculty: E.T.S.I. Agrónomos (UPM) [antigua denominación]
Department: Ingeniería Rural [hasta 2014]
Creative Commons Licenses: Recognition - No derivative works - Non commercial

Full text

[thumbnail of INVE_MEM_2012_140613.pdf]
Preview
PDF - Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (6MB) | Preview

Abstract

Through the use of the Distributed Fiber Optic Temperature Measurement (DFOT) method, it is possible to measure the temperature in small intervals (on the order of centimeters) for long distances (on the order of kilometers) with a high temporal frequency and great accuracy. The heat pulse method consists of applying a known amount of heat to the soil and monitoring the temperature evolution, which is primarily dependent on the soil moisture content. The use of both methods, which is called the active heat pulse method with fiber optic temperature sensing (AHFO), allows accurate soil moisture content measurements.
In order to experimentally study the wetting patterns, i.e. shape, size, and the water distribution, from a drip irrigation emitter, a soil column of 0.5 m of diameter and 0.6 m high was built. Inside the column, a fiber optic cable with a stainless steel sheath was placed forming three concentric helixes of diameters 0.2 m, 0.4 m and 0.6 m, leading to a 148 measurement point network. Before, during, and after the irrigation event, heat pulses were performed supplying electrical power of 20 W/m to the steel.
The soil moisture content was measured with a capacitive sensor in one location at depths of 0.1 m, 0.2 m, 0.3 m and 0.4 m during the irrigation. It was also determined by the gravimetric method in several locations and depths before and right after the irrigation.
The emitter bulb dimensions and shape evolution was satisfactorily measured during infiltration. Furthermore, some bulb's characteristics difficult to predict (e.g. preferential flow) were detected. The results point out that the AHFO is a useful tool to estimate the wetting pattern of drip irrigation emitters in soil columns and show a high potential for its use in the field.

More information

Item ID: 19097
DC Identifier: https://oa.upm.es/19097/
OAI Identifier: oai:oa.upm.es:19097
DOI: 10.1016/j.agwat.2012.10.012
Official URL: http://www.sciencedirect.com/science/article/pii/S...
Deposited by: Memoria Investigacion
Deposited on: 12 Sep 2013 15:05
Last Modified: 31 Mar 2015 22:56
  • Logo InvestigaM (UPM)
  • Logo GEOUP4
  • Logo Open Access
  • Open Access
  • Logo Sherpa/Romeo
    Check whether the anglo-saxon journal in which you have published an article allows you to also publish it under open access.
  • Logo Dulcinea
    Check whether the spanish journal in which you have published an article allows you to also publish it under open access.
  • Logo de Recolecta
  • Logo del Observatorio I+D+i UPM
  • Logo de OpenCourseWare UPM