Inspección técnica de la presa Santa Marta, mediante medidas subacuáticas de potencial espontáneo

Barragán Galeas, Vitelia (2013). Inspección técnica de la presa Santa Marta, mediante medidas subacuáticas de potencial espontáneo. Proyecto Fin de Carrera / Trabajo Fin de Grado, E.T.S.I. Minas (UPM).

Description

Title: Inspección técnica de la presa Santa Marta, mediante medidas subacuáticas de potencial espontáneo
Author/s:
  • Barragán Galeas, Vitelia
Contributor/s:
Item Type: Final Project
Date: June 2013
Subjects:
Faculty: E.T.S.I. Minas (UPM)
Department: Ingeniería Geológica [hasta 2014]
Creative Commons Licenses: Recognition - No derivative works - Non commercial

Full text

[thumbnail of PFC_VITELIA_BARRAGÁN_GALEAS.pdf]
Preview
PDF - Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (3MB) | Preview

Abstract

Las filtraciones de agua, con la consecuente erosión interna en presas de materiales sueltos, es una de las causas principales de fallos y accidentes. Las consecuencias del fallo de estas estructuras, pueden ser, pérdidas tanto económicas como de vidas humanas. Por lo cual en este proyecto se describe la aplicación de un método de prospección geofísica no invasiva, medidas de potencial espontáneo, para detectar posibles filtraciones de agua en el cuerpo de la presa. El flujo de agua a través de un material poroso y permeable crea un campo de potencial eléctrico de una magnitud de decenas o centenas de milivoltios, el cual puede ser medido y así detectar infiltraciones de agua en presas de materiales sueltos. Se ha aplicado esta técnica en la Presa Santa Marta, y mediante una interpretación cualitativa de los datos medidos, tomados en la cara aguas arriba de la presa (medidas subacuáticas), se logró identificar un flujo de agua vertical y otro subhorizontal, que estaban ingresando en el cuerpo de la presa, los cuales estaban causando erosión interna y la formación de una tubificación. ABSTRACT Water leakages and internal erosion in embankment dams is one of the main causes of failures and accidents. The consequences of the failure of these structures may cause losses both, economical and of human lives. Therefore, this project describes the application of a noninvasive geophysical prospecting method, self potential measurements, to detect water leakages in the body of the dam. Water flow through a porous and pervious medium creates an electric potential field with a magnitude of tens or hundreds of milivolts, which can be measured and thus detect water leakage in embankment dams. This technique has been applied to the Santa Marta dam, and through a qualitative self potential data interpretation, of the measurements obtained in an upstream direction (underwater measurements), a vertical and sub horizontal water flows entering in the body dam were identified, which were causing internal erosion and developing a piping

More information

Item ID: 19929
DC Identifier: https://oa.upm.es/19929/
OAI Identifier: oai:oa.upm.es:19929
Deposited by: Biblioteca ETSI Minas y Energía
Deposited on: 12 Sep 2013 08:58
Last Modified: 07 Mar 2018 08:45
  • Logo InvestigaM (UPM)
  • Logo GEOUP4
  • Logo Open Access
  • Open Access
  • Logo Sherpa/Romeo
    Check whether the anglo-saxon journal in which you have published an article allows you to also publish it under open access.
  • Logo Dulcinea
    Check whether the spanish journal in which you have published an article allows you to also publish it under open access.
  • Logo de Recolecta
  • Logo del Observatorio I+D+i UPM
  • Logo de OpenCourseWare UPM