Estudio Acústico del Teatro Tomás y Valiente de Fuenlabrada

Herranz Macías, Cristina (2013). Estudio Acústico del Teatro Tomás y Valiente de Fuenlabrada. Proyecto Fin de Carrera / Trabajo Fin de Grado, E.U.I.T. Telecomunicación (UPM), Madrid.

Description

Title: Estudio Acústico del Teatro Tomás y Valiente de Fuenlabrada
Author/s:
  • Herranz Macías, Cristina
Contributor/s:
Item Type: Final Project
Date: 26 September 2013
Subjects:
Faculty: E.U.I.T. Telecomunicación (UPM)
Department: Ingeniería Audiovisual y Comunicaciones
Creative Commons Licenses: Recognition - No derivative works - Non commercial

Full text

[thumbnail of PFC_CRISTINA_HERRANZ_MACIAS.pdf]
Preview
PDF - Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (5MB) | Preview

Abstract

El objetivo de este Proyecto Fin de Carrera es realizar el estudio de las características acústicas del Teatro Tomás y Valiente de Fuenlabrada mediante medidas y con el apoyo de
los resultados obtenidos mediante la simulación del campo sonoro.
El recinto está destinado principalmente a representaciones teatrales, empleándose también como sala polivalente, de forma que se analizará su comportamiento acústico e idoneidad ante la variedad de usos a los que se destina.
Para ello, se realizan medidas experimentales in situ de todos los parámetros representativos de un recinto acústico y la predicción de los mismos mediante la simulación de la sala a través del software de simulación acústica EASE, de forma que las características acústicas obtenidas mediante ambos procesos sean comparadas proponiéndose mejoras en el entorno para cumplimiento de parámetros acústicos óptimos
exigibles a la sala.
En primer lugar se exponen los principales conceptos teóricos a tener en cuenta en el ámbito de la acústica, detallando las diferentes teorías de estudio, los principios básicos de la psicoacústica.
Además, se definen los criterios utilizados en el diseño de recintos acústicos y parámetros que definan la calidad según el uso al que se destine en función del estudio de la utilización habitual de la sala y valores óptimos de los parámetros acústicos correspondientes a salas de tamaño y uso similar.
A continuación, se describe la metodología aplicada para la realización de las medidas in situ obteniendo resultados de los parámetros acústicos representativos del recinto para el
análisis de sus características acústicas y posterior comparación con la predicción de los mismos mediante la simulación del modelo informático.
También se muestra el proceso que se ha seguido para el diseño del modelo acústico a partir de los planos del teatro y medidas realizadas en el recinto, para la simulación de
parámetros y características acústicas.
Finalmente se exponen las conclusiones extraídas tras el estudio realizado y la propuesta de mejoras en el entorno para cumplimiento de parámetros acústicos óptimos que se
puedan exigir a esta sala, incluyendo un presupuesto que muestre la viabilidad económica del proyecto.
ABSTRACT.
The goal of this final project, is to perform an acoustic study and simulation of the Tomás y Valiente theatre in Fuenlabrada.
These premises are mainly used for stage plays, but also as a multipurpose space, therefore its acustic behaviour and suitability for the expected uses will be analyzed.
To accomplish this task, experimental measures for all the representative parameters for an acoustic hall, will be taken on site. The prediction for those measurements will be
simulated through EASE software, so the acoustic characteristics obtained using both methods will be compared, and improvements will be proposed in order to achieve the best acoustic parameters, the hall can have.
First at all, the theoretical concepts definition involves exposing the main concepts to consider in the acoustics field, detailing the basic principles of the psychoacoustic.
On top of the criteria used in the design of acoustic enclosures and parameters defining the quality according to the use the enclosure is intended for. Research on the most common usage for the space, and optimal values, comparing it with similar rooms in size and use.
Experimental measures are made of the acoustic parameters representative of the enclosure for the analysis of its acoustic characteristics and its later comparison with the prediction of the parameters through informatics model simulation.
Also the process which has been followed for the design of acoustic model of the theater are taken from on site measurements, experimental representative measures and acoustic parameters, for the acoustic characteristics analysis and post comparison with the software model simulation and prediction. Acoustic design of the theater taking as a base the building blueprints, and manual measures, for the parameters and acoustic characteristics
simulation.
Finally, the conclusions extracted after the performed research are shown and the propose of improvements in the environment for fulfillment of acoustic optimal parameters which can be required to this room, including a quote with shows the economical viability of the project.

More information

Item ID: 21961
DC Identifier: https://oa.upm.es/21961/
OAI Identifier: oai:oa.upm.es:21961
Deposited by: Biblioteca Universitaria Campus Sur
Deposited on: 13 Dec 2013 06:50
Last Modified: 21 Apr 2016 12:52
  • Logo InvestigaM (UPM)
  • Logo GEOUP4
  • Logo Open Access
  • Open Access
  • Logo Sherpa/Romeo
    Check whether the anglo-saxon journal in which you have published an article allows you to also publish it under open access.
  • Logo Dulcinea
    Check whether the spanish journal in which you have published an article allows you to also publish it under open access.
  • Logo de Recolecta
  • Logo del Observatorio I+D+i UPM
  • Logo de OpenCourseWare UPM