Moreton Villagra, Rodrigo and Martinez Moreno, Francisco and Lorenzo Pigueiras, Eduardo and Muñoz, Javier and Narvarte Fernández, Luis (2013). A 800 kW I-V curve. In: "28th European PV Solar Energy Conference and Exhibition", 30/09/2013 - 04/10/2013, Paris, France. pp. 1-4.
Title: | A 800 kW I-V curve |
---|---|
Author/s: |
|
Item Type: | Presentation at Congress or Conference (Article) |
Event Title: | 28th European PV Solar Energy Conference and Exhibition |
Event Dates: | 30/09/2013 - 04/10/2013 |
Event Location: | Paris, France |
Title of Book: | 28th European PV Solar Energy Conference and Exhibition |
Date: | 2013 |
Subjects: | |
Freetext Keywords: | I-V curve, in-field measurements, quality control, PV generator |
Faculty: | Instituto de Energía Solar (IES) (UPM) |
Department: | Electrónica Física |
Creative Commons Licenses: | Recognition - No derivative works - Non commercial |
![]() Preview |
PDF
- Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (295kB) |
This paper presents the measurement of the I-V curve of an 800 kW PV generator by means of an own-made capacitive load. Along the lines of some previous works, it is shown that an I-V curve analysis can also be applied to big PV generators and that, when measuring the operating conditions with reference modules and taking some precautions (especially regarding the operating cell temperature), it is still a useful tool for characterizing them and therefore can be incorporated into maintenance procedures. As far as we know, this is the largest I-V curve measured so far.