Diseño de una vivienda unifamiliar con instalación geotérmica de muy baja entalpía

Garrido López, Esther (2014). Diseño de una vivienda unifamiliar con instalación geotérmica de muy baja entalpía. Proyecto Fin de Carrera / Trabajo Fin de Grado, E.T.S.I. de Minas y Energía (UPM).

Description

Title: Diseño de una vivienda unifamiliar con instalación geotérmica de muy baja entalpía
Author/s:
  • Garrido López, Esther
Contributor/s:
Item Type: Final Project
Date: September 2014
Subjects:
Faculty: E.T.S.I. de Minas y Energía (UPM)
Department: Sistemas Energéticos [hasta 2014]
Creative Commons Licenses: Recognition - No derivative works - Non commercial

Full text

[thumbnail of PFC_Esther_Garrido_Lopez.pdf]
Preview
PDF - Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (36MB) | Preview

Abstract

El objetivo del presente proyecto es el diseño de una vivienda unifamiliar de manera que el aporte de energía no renovable sea el mínimo para conseguir las condiciones de confort óptimas para los ocupantes durante todo el año. Para su diseño se tendrá en cuenta el aporte de energía solar pasiva y el uso de aislantes térmicos a lo largo de la envolvente para la reducción de las necesidades de energía. Se dimensiona una instalación geotérmica para el abastecimiento de calefacción, refrigeración y agua caliente sanitaria (ACS). En este dimensionamiento se incluyen los sondeos geotérmicos, el equipo de bomba de calor y la instalación de suelo radiante. En el estudio de iluminación se analizan las necesidades de alumbrado de la vivienda utilizando luminarias led. Por último se evalúa la viabilidad económica que supone sustituir una instalación de caldera de gasoil por la instalación geotérmica dimensionada y la viabilidad de sustituir luminarias incandescentes por luminarias led. ABSTRACT The purpose of this paper is the design of a single family home with the lowest nonrenewable energy input, so optimum comfort living conditions for the occupants during the whole year can be reached. In order to design the house, both passive solar energy input and the use of thermal insulators will be taken into account. A geothermal installation for the heating, cooling and Domestic Hot Water (DHC) supply will be measured. In this measuring, the boreholls, the heat pump equipment and the radiant floor heating installation are included. In the study of illumination of the house, the lighting needs using LED luminaires are analised. Finally, the economic viability when replacing the installation of a diesel boiler for the measured geothermal installation is assessed, as well as the viability when replacing incandescent luminaires for LED luminaires

More information

Item ID: 32713
DC Identifier: https://oa.upm.es/32713/
OAI Identifier: oai:oa.upm.es:32713
Deposited by: Biblioteca ETSI Minas y Energía
Deposited on: 12 Nov 2014 11:31
Last Modified: 16 Mar 2018 12:15
  • Logo InvestigaM (UPM)
  • Logo GEOUP4
  • Logo Open Access
  • Open Access
  • Logo Sherpa/Romeo
    Check whether the anglo-saxon journal in which you have published an article allows you to also publish it under open access.
  • Logo Dulcinea
    Check whether the spanish journal in which you have published an article allows you to also publish it under open access.
  • Logo de Recolecta
  • Logo del Observatorio I+D+i UPM
  • Logo de OpenCourseWare UPM