Second international spectroradiometer intercomparison: results and impact on PV device calibration

Galleano, Roberto, Zaaiman, W., Strati, Cecilia, Bartocci, Simona, Pravettoni, Mauro, Marzoli, Mateo, Fucci, Raffaele, Leanza, Gianni, Timò, Gianluca, Minuto, Alessandro, Catena, Mario, Aleo, Francesco, Takagi, S., Akiyama, A., Nuñez Júdez, Rubén ORCID: https://orcid.org/0000-0001-9160-5416 and Belluardo, Giorgio (2015). Second international spectroradiometer intercomparison: results and impact on PV device calibration. "Progress in Photovoltaics", v. 23 (n. 7); pp. 929-938. ISSN 1062-7995. https://doi.org/10.1002/pip.2511.

Description

Title: Second international spectroradiometer intercomparison: results and impact on PV device calibration
Author/s:
  • Galleano, Roberto
  • Zaaiman, W.
  • Strati, Cecilia
  • Bartocci, Simona
  • Pravettoni, Mauro
  • Marzoli, Mateo
  • Fucci, Raffaele
  • Leanza, Gianni
  • Timò, Gianluca
  • Minuto, Alessandro
  • Catena, Mario
  • Aleo, Francesco
  • Takagi, S.
  • Akiyama, A.
  • Nuñez Júdez, Rubén https://orcid.org/0000-0001-9160-5416
  • Belluardo, Giorgio
Item Type: Article
Título de Revista/Publicación: Progress in Photovoltaics
Date: 2015
ISSN: 1062-7995
Volume: 23
Subjects:
Freetext Keywords: Solar radiation; solar cell; intercomparison; spectroradiometer; calibration
Faculty: Instituto de Energía Solar (IES) (UPM)
Department: Electrónica Física
Creative Commons Licenses: Recognition - No derivative works - Non commercial

Full text

[thumbnail of INVE_MEM_2015_235624.pdf]
Preview
PDF - Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (2MB) | Preview

Abstract

This paper describes the results of an intercomparison of spectroradiometers for measuring global normal incidence and direct normal incidence spectral irradiance in the visible and in the near infrared, together with an assessment of the impact these results may have on the calibration of the short circuit current (I-sc) of triple-junction photovoltaic devices and on the relevant spectral mismatch calculation. The intercomparison was conducted by six European scientific laboratories and a Japanese industrial partner. Seven spectroradiometer systems, for a total of 13 different instruments/channels using two different technologies and made by four different manufacturers were involved. This group of systems represents a good cross section of the instrumentation for solar spectrum measurements available to date. The instruments were calibrated by each partner prior to the intercomparison following their usual procedure and traceability route in order to verify the entire measurement and traceability chain. The difference in measured spectral irradiance showed to have an impact on the calibration of a set of Iso-Type cells varying from +/- 2% to +/- 14% for middle and bottom cell, respectively.

More information

Item ID: 43617
DC Identifier: https://oa.upm.es/43617/
OAI Identifier: oai:oa.upm.es:43617
DOI: 10.1002/pip.2511
Official URL: http://onlinelibrary.wiley.com/doi/10.1002/pip.251...
Deposited by: Memoria Investigacion
Deposited on: 26 Oct 2016 16:46
Last Modified: 26 Oct 2016 16:46
  • Logo InvestigaM (UPM)
  • Logo GEOUP4
  • Logo Open Access
  • Open Access
  • Logo Sherpa/Romeo
    Check whether the anglo-saxon journal in which you have published an article allows you to also publish it under open access.
  • Logo Dulcinea
    Check whether the spanish journal in which you have published an article allows you to also publish it under open access.
  • Logo de Recolecta
  • Logo del Observatorio I+D+i UPM
  • Logo de OpenCourseWare UPM