Download (2MB) | Preview |
Galleano, Roberto, Zaaiman, W., Strati, Cecilia, Bartocci, Simona, Pravettoni, Mauro, Marzoli, Mateo, Fucci, Raffaele, Leanza, Gianni, Timò, Gianluca, Minuto, Alessandro, Catena, Mario, Aleo, Francesco, Takagi, S., Akiyama, A., Nuñez Júdez, Rubén ORCID: https://orcid.org/0000-0001-9160-5416 and Belluardo, Giorgio
(2015).
Second international spectroradiometer intercomparison: results and impact on PV device calibration.
"Progress in Photovoltaics", v. 23
(n. 7);
pp. 929-938.
ISSN 1062-7995.
https://doi.org/10.1002/pip.2511.
Title: | Second international spectroradiometer intercomparison: results and impact on PV device calibration |
---|---|
Author/s: |
|
Item Type: | Article |
Título de Revista/Publicación: | Progress in Photovoltaics |
Date: | 2015 |
ISSN: | 1062-7995 |
Volume: | 23 |
Subjects: | |
Freetext Keywords: | Solar radiation; solar cell; intercomparison; spectroradiometer; calibration |
Faculty: | Instituto de Energía Solar (IES) (UPM) |
Department: | Electrónica Física |
Creative Commons Licenses: | Recognition - No derivative works - Non commercial |
Preview |
PDF
- Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (2MB) | Preview |
This paper describes the results of an intercomparison of spectroradiometers for measuring global normal incidence and direct normal incidence spectral irradiance in the visible and in the near infrared, together with an assessment of the impact these results may have on the calibration of the short circuit current (I-sc) of triple-junction photovoltaic devices and on the relevant spectral mismatch calculation. The intercomparison was conducted by six European scientific laboratories and a Japanese industrial partner. Seven spectroradiometer systems, for a total of 13 different instruments/channels using two different technologies and made by four different manufacturers were involved. This group of systems represents a good cross section of the instrumentation for solar spectrum measurements available to date. The instruments were calibrated by each partner prior to the intercomparison following their usual procedure and traceability route in order to verify the entire measurement and traceability chain. The difference in measured spectral irradiance showed to have an impact on the calibration of a set of Iso-Type cells varying from +/- 2% to +/- 14% for middle and bottom cell, respectively.
Item ID: | 43617 |
---|---|
DC Identifier: | https://oa.upm.es/43617/ |
OAI Identifier: | oai:oa.upm.es:43617 |
DOI: | 10.1002/pip.2511 |
Official URL: | http://onlinelibrary.wiley.com/doi/10.1002/pip.251... |
Deposited by: | Memoria Investigacion |
Deposited on: | 26 Oct 2016 16:46 |
Last Modified: | 26 Oct 2016 16:46 |