Ramos Cenzano, Álvaro and Ogueta Gutiérrez, Mikel and Pindado Carrion, Santiago (2019). On the output frequency measurement within cup anemometer calibrations. "Measurement", v. 136 ; pp. 718-723. ISSN 0263-2241. https://doi.org/10.1016/j.measurement.2019.01.015.
Title: | On the output frequency measurement within cup anemometer calibrations |
---|---|
Author/s: |
|
Item Type: | Article |
Título de Revista/Publicación: | Measurement |
Date: | January 2019 |
ISSN: | 0263-2241 |
Volume: | 136 |
Subjects: | |
Freetext Keywords: | Cup anemometer. Anemometer calibration. Output frequency. FFT |
Faculty: | Instituto de Microgravedad Ignacio Da Riva (UPM) |
Department: | Sistemas Aeroespaciales, Transporte Aéreo y Aeropuertos |
UPM's Research Group: | Desarrollo y Ensayos Aeroespaciales DEA |
Creative Commons Licenses: | Recognition - No derivative works - Non commercial |
Preview |
PDF
- Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (397kB) | Preview |
The output frequency of five commercial anemometers (Thies Clima First-Class Advanced) was studied. The output voltage of these anemometers was measured at the calibrations process at 25 kHz sampling frequency, during 25 s. The output frequency was calculated by two different procedures: by Counting Pulses (CP) and by using the Fast Fourier Transform (FFT). The errors of the anemometers’ transfer function based on both ways for calculating the output frequency are given in relation to the reference calibration results, obtained with an ISO 17025 standard calibration process. The effect of the sampling frequency and the length of the sample are analyzed. The results of using FFT are compared to the ones resulting from using CP. Counting Pulses (CP) has proven to be the most accurate way to extract the anemometer’s output frequency from data recorded.
Item ID: | 53843 |
---|---|
DC Identifier: | https://oa.upm.es/53843/ |
OAI Identifier: | oai:oa.upm.es:53843 |
DOI: | 10.1016/j.measurement.2019.01.015 |
Official URL: | https://www.sciencedirect.com/science/article/pii/... |
Deposited by: | Biblioteca ETSI Aeronauticos |
Deposited on: | 07 Feb 2019 11:41 |
Last Modified: | 28 Feb 2023 09:27 |