Martínez Pérez, Inmaculada and Valivonis, Jouzas and González García, María de las Nieves and González Rodrigo, Sonsoles (2018). Experimental study of layered steel fibre reinforced concrete beams. In: "III Congreso Internacional de Innovación Tecnológica en Edificación (CITE 2018)", 7-9 marzo 2018, Madrid, España. ISBN 978-84-16397-71-6. pp. 234-235.
Title: | Experimental study of layered steel fibre reinforced concrete beams |
---|---|
Author/s: |
|
Item Type: | Presentation at Congress or Conference (Other) |
Event Title: | III Congreso Internacional de Innovación Tecnológica en Edificación (CITE 2018) |
Event Dates: | 7-9 marzo 2018 |
Event Location: | Madrid, España |
Title of Book: | CITE 2018 : III Congreso Internacional de Innovación Tecnológica en Edificación : libro de actas |
Date: | 2018 |
ISBN: | 978-84-16397-71-6 |
Subjects: | |
Freetext Keywords: | Steel fiber, Reinforced concrete, Ductility, Mechanical behavior |
Faculty: | E.T.S. de Edificación (UPM) |
Department: | Construcciones Arquitectónicas y su Control |
Creative Commons Licenses: | Recognition - No derivative works - Non commercial |
Preview |
PDF
- Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (557kB) | Preview |
There are many research works that analyze the effects of corrosion on the tensile strength, deformation and ductile behavior of corrugated steel reinforcements. The analysis of this influence has been developed on bars of different diameters. This paper study the variations in the mechanical properties of steel that occur in small diameter hot-rolled corrugated steel reinforcements, in which corrosion has been accelerated, affecting different lengths of them. For the test carrying out, bars of 50 cm length have been embedded in slabs of cement mortar with a proportion of 4% of calcium chloride. Then, they have undergone an accelerated corrosion, connecting them to variable amounts of current during different periods of time. Subsequently, the corroded bars have been extracted and subjected to a standardized tensile test, which has allowed to know the strength characteristics according to the area affected by corrosion, always referred to a set of standard bars.
Item ID: | 54174 |
---|---|
DC Identifier: | https://oa.upm.es/54174/ |
OAI Identifier: | oai:oa.upm.es:54174 |
Deposited by: | Memoria Investigacion |
Deposited on: | 11 Apr 2019 11:33 |
Last Modified: | 11 Apr 2019 11:33 |