Comparativa de un edificio Passivhaus y un edificio según CTE

Fernández García, Natalia (2019). Comparativa de un edificio Passivhaus y un edificio según CTE. Thesis (Master thesis), E.T.S.I. de Minas y Energía (UPM).

Description

Title: Comparativa de un edificio Passivhaus y un edificio según CTE
Author/s:
  • Fernández García, Natalia
Contributor/s:
Item Type: Thesis (Master thesis)
Masters title: Eficiencia Energética en la Edificación, la Industria y el Transporte
Date: June 2019
Subjects:
Faculty: E.T.S.I. de Minas y Energía (UPM)
Department: Energía y Combustibles
Creative Commons Licenses: Recognition - No derivative works - Non commercial

Full text

[thumbnail of TFM_NATALIA_FERNANDEZ_GARCIA.pdf]
Preview
PDF - Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (8MB) | Preview

Abstract

El presente Trabajo de Fin de Máster desarrolla un estudio que tiene como base la comparativa entre dos estándares de construcción: el estándar Passivhaus y el estándar del Código Técnico de la Edificación. En la comparativa del edificio se incluye un estudio térmico (demanda energética, cargas térmicas, consumo energético), los equipos para satisfacer las necesidades del edificio (climatización y producción de agua caliente sanitaria), emisiones producidas por los equipos, costes de cerramientos del edificio y de equipos, y amortización. La citada comparativa se realiza para un edificio sito en Madrid. La segunda parte del trabajo desarrolla una comparación del estudio térmico de varias ciudades con climatologías opuestas. Este trabajo ha sido realizado empleando el software CYPECAD MEP, junto con manuales de instrucciones y tutoriales. Todos los datos de este trabajo han sido obtenidos, de manera personal, a partir de múltiples iteraciones para demostrar todos los beneficios del estándar Passivhaus. The present Final Master Thesis develops a study based on a comparative between two construction standards: Passivhaus standard and Technical Building Code (Spain). This comparison includes a thermal study (energy demand, thermal loads, energy consumption), equipment to meet the building’s needs (air conditioning and hot water production), emissions produced by the equipment, costs of building enclosures and equipment, and amortization. The aforementioned comparison is made for a building located in Madrid. The second part of the thesis develops a comparison of the thermal study of several cities with opposite climates. This thesis has been done using the CYPECAD MEP software, along with instruction manual and tutorials. All data of this thesis have been obtained, in a personal way, from multiple iterations, to demonstrate all the benefits of the Passivhaus standard.

More information

Item ID: 57297
DC Identifier: https://oa.upm.es/57297/
OAI Identifier: oai:oa.upm.es:57297
Deposited by: Biblioteca ETSI Minas y Energía
Deposited on: 15 Nov 2019 09:06
Last Modified: 01 Apr 2020 22:30
  • Logo InvestigaM (UPM)
  • Logo GEOUP4
  • Logo Open Access
  • Open Access
  • Logo Sherpa/Romeo
    Check whether the anglo-saxon journal in which you have published an article allows you to also publish it under open access.
  • Logo Dulcinea
    Check whether the spanish journal in which you have published an article allows you to also publish it under open access.
  • Logo de Recolecta
  • Logo del Observatorio I+D+i UPM
  • Logo de OpenCourseWare UPM