Calibration setup for traceable measurements of very fast transients

Khamlichi, Abderrahim, Garnacho Vecino, Fernando ORCID: https://orcid.org/0000-0002-7752-8810, Hällström, Jari, Elg, Alf-Peter and Rovira, Jorge (2019). Calibration setup for traceable measurements of very fast transients. In: "21st International Symposium on High Voltage Engineering. ISH 2019", 26/08/2019-30/08/2019, Budapest, Hungría. pp. 1-6. https://doi.org/10.5281/zenodo.3238169.

Description

Title: Calibration setup for traceable measurements of very fast transients
Author/s:
Item Type: Presentation at Congress or Conference (Article)
Event Title: 21st International Symposium on High Voltage Engineering. ISH 2019
Event Dates: 26/08/2019-30/08/2019
Event Location: Budapest, Hungría
Title of Book: 21st International Symposium on High Voltage Engineering
Date: 4 June 2019
Subjects:
Faculty: E.T.S.I. Diseño Industrial (UPM)
Department: Ingeniería Eléctrica, Electrónica Automática y Física Aplicada
Creative Commons Licenses: Recognition - No derivative works - Non commercial

Full text

[thumbnail of INVE_MEM_2019_326418.pdf]
Preview
PDF - Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (791kB) | Preview

Abstract

Wideband sensors like D-dot probes or capacitive probes are used to measure very fast transient overvoltages, but there is no recognized traceability for this kind of measurements. In the present version of IEC 61869-1, the test conditions for both GIS and air-insulated systems are given, but there is no guidance on the measurement methods that are used to assess the uncertainty of measurements because of a lack of traceability for HV transients. A calibration SF₆ set-up has been developed to establish the European traceability in this field. This paper presents this VFT calibration setup composed by a step voltage generator up to 100 kV with a rise time less than 10 ns, and a reference measuring system. The calibration setup of 7 m length is based on a cylindrical SF₆ configuration, which uses a stainless-steel duct with an outside diameter of 500 mm and an internal aluminium tube of 200 mm diameter as a high voltage conductor to have characteristic impedance around 50Ω, as a representative figure of the SF₆ GIS. A spark-gap of SF₆ at 2 bars is used to achieve a pulse with a rise time of less than 10 ns. Conical elements allow a good impedance matching between different sections of the calibration setup. The probe to be calibrated is either installed in a duct window in the case of a capacitive probe, or mounted in an intermediate flange between two duct elements in the case of a D-dot probe. A fast resistive reference measuring system is installed at the end of the metallic duct. A wideband digital recorder of 400 MHz of bandwidth, 14-bit of vertical resolution and 4.5 ns settling time is used to acquire and analyse the generated VFT pulses. The paper describes the design of the calibration setup and its characterization.

Funding Projects

Type
Code
Acronym
Leader
Title
Horizon 2020
15NRM02
UHV
Alf-Peter Elg (RISE)
European Metrology Programme for Innovation and Research (EMPIR 2015): Pre-Co-Normative: Techniques for ultra-high voltage and very fast transients

More information

Item ID: 65289
DC Identifier: https://oa.upm.es/65289/
OAI Identifier: oai:oa.upm.es:65289
DOI: 10.5281/zenodo.3238169
Official URL: http://ish2019.org/
Deposited by: Memoria Investigacion
Deposited on: 17 Nov 2020 08:49
Last Modified: 17 Nov 2020 08:49
  • Logo InvestigaM (UPM)
  • Logo GEOUP4
  • Logo Open Access
  • Open Access
  • Logo Sherpa/Romeo
    Check whether the anglo-saxon journal in which you have published an article allows you to also publish it under open access.
  • Logo Dulcinea
    Check whether the spanish journal in which you have published an article allows you to also publish it under open access.
  • Logo de Recolecta
  • Logo del Observatorio I+D+i UPM
  • Logo de OpenCourseWare UPM