Transient overvoltage distribution in sectionalized screens of HV joints

Khamlichi, Abderrahim, Denche Castejón, Gregorio ORCID: https://orcid.org/0000-0001-7451-0183, Garnacho Vecino, Fernando ORCID: https://orcid.org/0000-0002-7752-8810 and Balza López, Xabier (2019). Transient overvoltage distribution in sectionalized screens of HV joints. In: "Jicable'19: International Conference on Cables and LV, MV, HV & EHV Cables and Cable Systems", 23/06/2019-27/06/2019, Versalles, Francia. pp. 1-6.

Description

Title: Transient overvoltage distribution in sectionalized screens of HV joints
Author/s:
Item Type: Presentation at Congress or Conference (Article)
Event Title: Jicable'19: International Conference on Cables and LV, MV, HV & EHV Cables and Cable Systems
Event Dates: 23/06/2019-27/06/2019
Event Location: Versalles, Francia
Title of Book: Jicable'19: International Conference on Cables and LV, MV, HV & EHV Cables and Cable Systems
Date: 2019
Subjects:
Freetext Keywords: Sectionalized joints; Surge voltage limiters; Link-boxes; Bonding lead cables; Transient overvoltages; Lightning
Faculty: E.T.S.I. Diseño Industrial (UPM)
Department: Ingeniería Eléctrica, Electrónica Automática y Física Aplicada
Creative Commons Licenses: Recognition - No derivative works - Non commercial

Full text

[thumbnail of INVE_MEM_2019_326478.pdf]
Preview
PDF - Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (846kB) | Preview

Abstract

(ENG)The overvoltages between screens of the sectionalized joints depend not only on the chosen surge voltage limiters, but also on the type of bonding lead cable used to connect them. Connection cables of unipolar type instead of coaxial lead to higher overvoltages. This negative influence is accentuated the longer the length of the bonding lead cable. This article demonstrates the use of unipolar cable is equivalent to increasing the length of the cable more than 5 times that of the coaxial cable. The article also analyses the voltage distribution between each screen of a joint with respect to earth.(SPA)Se presenta las sobretensiones que aparecen en las pantallas seccionadas de los empalmes de los cables de alta tensión cuando una sobretensión transitoria recorre el cable. Los casos estudiados corresponden a configuraciones cross-bonding con y sin limitadores de sobretensión.

More information

Item ID: 65298
DC Identifier: https://oa.upm.es/65298/
OAI Identifier: oai:oa.upm.es:65298
Official URL: http://www.jicable.org/Former_Conferences/ssession...
Deposited by: Memoria Investigacion
Deposited on: 12 Nov 2020 10:48
Last Modified: 12 Nov 2020 10:48
  • Logo InvestigaM (UPM)
  • Logo GEOUP4
  • Logo Open Access
  • Open Access
  • Logo Sherpa/Romeo
    Check whether the anglo-saxon journal in which you have published an article allows you to also publish it under open access.
  • Logo Dulcinea
    Check whether the spanish journal in which you have published an article allows you to also publish it under open access.
  • Logo de Recolecta
  • Logo del Observatorio I+D+i UPM
  • Logo de OpenCourseWare UPM