Ensayos alternativos para la determinación del tiempo de fraguado. Métodos capacitivo y resistivo = Alternative tests for the determination of the setting time. Capacitive and resistive methods

Ferrández Vega, Daniel ORCID: https://orcid.org/0000-0003-0226-431X, Yedra, Engerst, Morón Fernández, Carlos ORCID: https://orcid.org/0000-0002-6928-5134 and Morón Barrios, Alberto (2020). Ensayos alternativos para la determinación del tiempo de fraguado. Métodos capacitivo y resistivo = Alternative tests for the determination of the setting time. Capacitive and resistive methods. "Dyna", v. 95 (n. 3); pp. 294-298. ISSN 0012-7361. https://doi.org/10.6036/9741.

Description

Title: Ensayos alternativos para la determinación del tiempo de fraguado. Métodos capacitivo y resistivo = Alternative tests for the determination of the setting time. Capacitive and resistive methods
Author/s:
Item Type: Article
Título de Revista/Publicación: Dyna
Date: April 2020
ISSN: 0012-7361
Volume: 95
Subjects:
Freetext Keywords: Hardening time, Vicat needle, Capacitive sensor, Arduino = Tiempo de fraguado, Aguja de Vicat, Sensor capacitivo, Arduino
Faculty: E.T.S. de Edificación (UPM)
Department: Tecnología de la Edificación
Creative Commons Licenses: Recognition - No derivative works - Non commercial

Full text

[thumbnail of INVE_MEM_2020_339421.pdf]
Preview
PDF - Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (514kB) | Preview

Abstract

El fraguado de los materiales conglomerantes se caracteriza por el cambio de estado de la pasta, de un estado fluido -después del amasado-, a su estado sólido. En la actualidad se emplea el conocido Método de la Aguja de Vicat para la determinación de los tiempos de fraguado, de acuerdo con las normas UNE-EN 13279-2 y UNE-EN 196-3, según se trate de yesos y escayolas o de cementos. En este trabajo se proponen dos métodos alternativos de bajo coste y fácilmente aplicables, basados en un sensor capacitivo y en un sensor resistivo, los cuales pueden ayudar a mejorar el proceso de producción de prefabricados de construcción. Los resultados muestran cómo es posible relacionar los tiempos de fraguado medidos convencionalmente con las variaciones en la respuesta de los sensores implementados. Por otra parte, se consigue monitorizar en tiempo real el comportamiento del material sin tener que depender de un ensayo manual. Este trabajo muestra la viabilidad de ambos métodos alternativos para la determinación del tiempo de fraguado en materiales conglomerantes. ----------ABSTRACT---------- The hardening of the conglomerates’ materials is characterized by the change in the state of the paste, from a fluid state -after mixing- to its solid-state. At present, the well-known Vicat Needle Method is used to determine the hardening times, following the UNE-EN 13279-2 and UNE-EN 196-3 standards, depending on whether they are gypsum, plaster or cement. In this work, two alternative low-cost methods and easily applicable are proposed, based on capacitive and resistive sensors, which can help to improve the production process of prefabricated construction. The results show how it is possible to relate the setting times conventionally measured with the variations in the response of the sensors implemented. On the other hand, the behavior of the material can be monitored in real-time without having to rely on a manual test. This work, therefore, validates two alternative methods for the testing of conglomerates’ materials.

More information

Item ID: 68505
DC Identifier: https://oa.upm.es/68505/
OAI Identifier: oai:oa.upm.es:68505
DOI: 10.6036/9741
Official URL: https://www.revistadyna.com/busqueda/ensayos-alter...
Deposited by: Memoria Investigacion
Deposited on: 27 Sep 2021 09:30
Last Modified: 27 Sep 2021 11:02
  • Logo InvestigaM (UPM)
  • Logo GEOUP4
  • Logo Open Access
  • Open Access
  • Logo Sherpa/Romeo
    Check whether the anglo-saxon journal in which you have published an article allows you to also publish it under open access.
  • Logo Dulcinea
    Check whether the spanish journal in which you have published an article allows you to also publish it under open access.
  • Logo de Recolecta
  • Logo del Observatorio I+D+i UPM
  • Logo de OpenCourseWare UPM