Pérez Díaz, Juan Ignacio ORCID: https://orcid.org/0000-0003-0657-8527, Perea, Alejandro and Wilhelmi Ayza, José-Román
(2010).
Optimal short-term operation and sizing of pumped-storage power plants in systems with high penetration of wind energy.
In: "7th International Conference on the European Energy Market (EEM), 2010", 23/06/2010 - 25/06/2010, Madrid, España. ISBN 978-1-4244-6838-6.
Title: | Optimal short-term operation and sizing of pumped-storage power plants in systems with high penetration of wind energy |
---|---|
Author/s: |
|
Item Type: | Presentation at Congress or Conference (Article) |
Event Title: | 7th International Conference on the European Energy Market (EEM), 2010 |
Event Dates: | 23/06/2010 - 25/06/2010 |
Event Location: | Madrid, España |
Title of Book: | Proceedings of the 7th International Conference on the European Energy Market (EEM), 2010 |
Date: | August 2010 |
ISBN: | 978-1-4244-6838-6 |
Subjects: | |
Faculty: | E.T.S.I. Caminos, Canales y Puertos (UPM) |
Department: | Ingeniería Civil: Hidráulica y Energética [hasta 2014] |
Creative Commons Licenses: | Recognition - No derivative works - Non commercial |
Preview |
PDF
- Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (662kB) | Preview |
In this paper the short-term optimal operation of an electric system comprising several thermal power plants and one pumped storage plant is studied in several scenarios of power demand and wind penetration in order to draw conclusions about the contribution of the pumped storage plant to system operation costs. A mixed integer linear programming model is used to obtain the optimal hourly thermal, hydro and pumping powers so that the production cost of the entire system is minimized. An aggregated piecewise linear hourly production cost curve is used to represent the thermal generation; the marginal production cost varying as a function of the power generated according to the slope of each piecewise linear segment. Main design parameters of the pumped storage plant are not considered fixed in the model but rather they are obtained in the solution with the purpose of drawing conclusions about the plant optimal sizing