Alou Cervera, Pedro and García Suárez, Oscar and Oliver Ramírez, Jesús Angel and Cobos Márquez, José Antonio and Viejo de Frutos, Miriam del (2010). Fast control technique based on peak current mode control of the output capacitor current. In: "2010 IEEE Energy Conversion Congress and Expo (ECCE)", 12/09/2010 - 16/09/2010, Atlanta, Georgia, EEUU. ISBN 978-1-4244-5286-6.
Title: | Fast control technique based on peak current mode control of the output capacitor current |
---|---|
Author/s: |
|
Item Type: | Presentation at Congress or Conference (Article) |
Event Title: | 2010 IEEE Energy Conversion Congress and Expo (ECCE) |
Event Dates: | 12/09/2010 - 16/09/2010 |
Event Location: | Atlanta, Georgia, EEUU |
Title of Book: | Proceedings of the 2010 IEEE Energy Conversion Congress and Expo (ECCE) |
Date: | 2010 |
ISBN: | 978-1-4244-5286-6 |
Subjects: | |
Faculty: | E.T.S.I. Industriales (UPM) |
Department: | Automática, Ingeniería Electrónica e Informática Industrial [hasta 2014] |
Creative Commons Licenses: | Recognition - No derivative works - Non commercial |
Preview |
PDF
- Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (1MB) | Preview |
The control proposed and analyzed in this paper is based on the peak current mode control of the output capacitor current of a Buck converter. The output capacitor current loop provides fast dynamic response to the control since it behaves as a feed-forward of the load current while the voltage loop provides accurate steady state regulation. A simulation oriented averaged model of the proposed control has been developed to design the external voltage loop. As shown in simulations, with the converter switching at 5 MHz, the proposed control with a voltage loop of 50 kHz bandwidth has the same voltage drop and a similar dynamic response as a 1 MHz bandwidth voltage mode control. The reduction of the bandwidth makes easier the control implementation and integration. Finally, experimental results have been achieved verifying the fast dynamic response of the proposed control under load steps