Full text
Preview |
PDF
- Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (2MB) | Preview |
Castillo Talavera, Ángel, Andrade Perdrix, María del Carmen, Martinez, I., Rebolledo Ramos, Nuria, Fernández Troyano, Leonardo, Ayuso, G., Cuervo, J., Junquera, J. and Santana, C. (2010). Monitoring of Zarzuela Racecourse structure by means of no-destructive techniques for durability assessment.. In: "6th international conference on concrete under severe conditions (CONSEC '10)", 07/06/2010 - 09/06/2010, Mérida, Yucatán, Méjico. ISBN 978-0-415-59317-5.
Title: | Monitoring of Zarzuela Racecourse structure by means of no-destructive techniques for durability assessment. |
---|---|
Author/s: |
|
Item Type: | Presentation at Congress or Conference (Article) |
Event Title: | 6th international conference on concrete under severe conditions (CONSEC '10) |
Event Dates: | 07/06/2010 - 09/06/2010 |
Event Location: | Mérida, Yucatán, Méjico |
Title of Book: | Proceedings of the 6th international conference on concrete under severe conditions (CONSEC '10) |
Date: | 2010 |
ISBN: | 978-0-415-59317-5 |
Subjects: | |
Faculty: | E.T.S.I. Caminos, Canales y Puertos (UPM) |
Department: | Otro |
Creative Commons Licenses: | Recognition - No derivative works - Non commercial |
Preview |
PDF
- Requires a PDF viewer, such as GSview, Xpdf or Adobe Acrobat Reader
Download (2MB) | Preview |
Present paper describes some aspects of the restoration project recently undertaken in La Zarzuela Racecourse, designed by E. Torroja and Dominguez in 1934. Despite the good mechanical work of steel, it has started a deterioration process which has caused the corrosion of reinforcement by carbonation. It has been detected corrosion attack in some places due the breaking of the upper waterproofing membrane of the shell which enabled the water to remain long periods in the roof and therefore promoted corrosion of reinforcement. For the repair first an assessment of the degree of corrosion was made. The restoration project finally consisted in the injection of all the cracks in order to assure the joint work of the shell and the patching of the deteriorated zones. Profiting these works it was installed a monitoring system of corrosion sensors. Results of the recording are given in the paper.
Item ID: | 9311 |
---|---|
DC Identifier: | https://oa.upm.es/9311/ |
OAI Identifier: | oai:oa.upm.es:9311 |
Deposited by: | Memoria Investigacion |
Deposited on: | 27 Oct 2011 09:40 |
Last Modified: | 14 May 2020 08:34 |