eprintid: 15313 rev_number: 18 eprint_status: archive userid: 1903 dir: disk0/00/01/53/13 datestamp: 2013-06-21 10:59:02 lastmod: 2014-09-22 11:07:33 status_changed: 2013-06-21 15:44:15 type: article metadata_visibility: show item_issues_count: 0 creators_name: Blázquez, Juan creators_name: Vallejo, I. creators_name: García-Berrocal Sánchez, Agustin creators_name: Balbás Antón, Miguel title: Control rod drop surveillance using two friction coefficients ispublished: pub subjects: fisica abstract: In the case of large burnup, a control rod (CR) guide tube in the pressurized water reactor of a commercial nuclear power plant might bend. As a consequence, a CR drop experiment may indicate an event of a CR partially inserted and whether the CR should be deemed inoperable. Early prevention of such an event can be achieved by measuring two friction coefficients: the hydraulic coefficient and the sliding coefficient. The hydraulic coefficient hardly changes, so that the curvature of the guide tube can only be detected thanks to a variation of the sliding coefficient. A simple model for the CR drop is established and validated with CR drop experiments. If tmx denotes the instant of CR maximum velocity, a linear relationship between (tmx)_2 and the sliding coefficient is found. date: 2011-11 date_type: published publisher: American Nuclear Society official_url: http://www.ans.org/store/j_13302 full_text_status: restricted publication: Nuclear Technology volume: 176 number: 2 pagerange: 284-289 institution: Minas department: Fisica5 refereed: TRUE issn: 0029-5450 rights: by-nc-nd citation: Blázquez, Juan and Vallejo, I. and García-Berrocal Sánchez, Agustin and Balbás Antón, Miguel (2011). Control rod drop surveillance using two friction coefficients. "Nuclear Technology", v. 176 (n. 2); pp. 284-289. ISSN 0029-5450. document_url: https://oa.upm.es/15313/1/INVE_MEM_2011_123596.pdf