TY - CONF M2 - Albuquerque, New Mexico, USA KW - Thermal resistance KW - CPV KW - cell temperature KW - wind KW - operation conditions A1 - Nuńez Júdez, Rubén A1 - Anton Hernandez, Ignacio A1 - Askins, Stephen A1 - Sala Pano, Gabriel A1 - Araki, Kenji UR - https://oa.upm.es/38829/ ID - upm38829 SN - 0094-243X EP - 148 Y1 - 2014/// TI - Characterization of CPV arrays based on differences on their thermal resistances N2 - Thermal characterization of Concentrating Photovoltaics (CPV) modules and Arrays is needed to determine their performance and modelling of energy forecast. Module-ambient thermal resistance is easily obtained from its definition but the cell-module thermal resistant needs to be estimated from indirect procedures, two of them are presented in this paper. In addition, an equivalent parameter is defined, the Concentrator Nominal Operating Module/Cell Temperature (CNOMT/CNOCT), the temperature at Concentrator Standard Operating Conditions (CSOC). Definitions and expression to relate (CNOMT/CNOCT) to thermal resistances are presented, plus several examples of estimations from real operating arrays. T2 - 10th International Conference on Concentrator Photovoltaic Systems (CPV-10) PB - American Institute of Physics AV - public SP - 144 ER -