?url_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&rft.title=Adaptaci%C3%B3n+a+la+integraci%C3%B3n+en+edificios+de+los+procedimientos+de+determinaci%C3%B3n+de+la+temperatura+de+los+m%C3%B3dulos+fotovoltaicos+en+centrales&rft.creator=San+Miguel+Alburquerque%2C+V%C3%ADctor&rft.contributor=Ramos+Mill%C3%A1n%2C+Alberto&rft.subject=Electric+Power&rft.description=En+este+trabajo+se+ha+tratado+de+validar+los+modelos+est%C3%A1ndar+de+la+NMOT+(IEC+61853)+y+TONC+(IEC+61215)+incluidos+en+las+normas+relativas+a+los+m%C3%B3dulos+fotovoltaicos+en+centrales%2C+para+su+uso+en+integraci%C3%B3n+en+edificios%2C+pero+con+par%C3%A1metros+de+ajuste+diferentes%2C+seg%C3%BAn+las+aplicaciones+arquitect%C3%B3nicas+en+las+que+se+integren+los+m%C3%B3dulos.+Las+bondades+de+ajuste+y+los+par%C3%A1metros+obtenidos+en+cada+caso+son+diferentes%2C+seg%C3%BAn+el+tipo+de+inclinaci%C3%B3n+y+ventilaci%C3%B3n+del+m%C3%B3dulo.+Como+esa+temperatura+del+m%C3%B3dulo+afecta+a+su+potencia+y%2C+por+tanto%2C+a+la+energ%C3%ADa+fotovoltaica+producida%2C+ajustar+los+modelos+a+las+nuevas+condiciones%2C+ha+permitido+evaluar+en+qu%C3%A9+medida+es+aceptable+o+no+considerar+los+modelos+tradicionales%2C+justific%C3%A1ndose+en+los+casos+que+proceda+la+utilizaci%C3%B3n+de+las+nuevas+expresiones.+Para+ello%2C+se+ha+hecho+una+comparaci%C3%B3n+emp%C3%ADrica+entre+la+temperatura+nominal+de+los+m%C3%B3dulos+empleados+en+integraci%C3%B3n+arquitect%C3%B3nica+y+la+temperatura+nominal+te%C3%B3rica+que+prev%C3%A9n+las+normas+IEC+61215+e+IEC+61853.+Se+colocaron+los+m%C3%B3dulos+objeto+de+estudio+en+dos+posiciones+distintas%2C+primeramente%2C+en+vertical+y+posteriormente+con+una+inclinaci%C3%B3n+de+45%C2%BA+respecto+al+suelo.+En+ambas+posiciones+se+estuvieron+monitorizando+la+temperatura%2C+irradiancia%2C+velocidad+y+direcci%C3%B3n+de+viento+durante+al+menos+un+mes.+Debe+darse+especial+importancia+a+la+inclusi%C3%B3n+de+la+parametrizaci%C3%B3n+del+viento+para+estimar+la+temperatura+del+m%C3%B3dulo+fotovoltaico.+Los+datos+se+han+ajustado+mediante+un+an%C3%A1lisis+de+regresi%C3%B3n+lineal+a+los+modelos+y+se+ha+realizado+un+estudio+de+la+bondad+de+los+ajustes+mediante+el+uso+de+estad%C3%ADsticos+y+el+programa+SPSS.+Como+resultado+del+estudio+se+constat%C3%B3+que%2C+aunque+las+expresiones+de+las+temperaturas+nominales+de+ambas+normas+son+aplicables+a+m%C3%B3dulos+integrados+en+fachadas+verticales%2C+siendo+el+grado+de+ajuste+al+modelo+mejor+en+los+casos+en+los+que+los+m%C3%B3dulos+est%C3%A1n+ventilados+o+semi-ventilados%2C+los+valores+de+las+temperaturas+nominales+que+se+ajustan+por+regresi%C3%B3n+al+modelo+no+lo+son.+Se+ha+analizado+qu%C3%A9+error+se+comete+en+cada+caso+en+la+estimaci%C3%B3n+anual+de+la+energ%C3%ADa+generada+por+considerar+la+temperatura+nominal+tradicional+en+vez+de+la+ajustada+experimentalmente+para+cada+aplicaci%C3%B3n+de+integraci%C3%B3n+en+edificio.+Los+errores+var%C3%ADan+entre+el+1%25+para+fachada+vertical+ventilada+y+el+7%25+para+fachada+vertical+sin+ventilaci%C3%B3n.+ABSTRACT+In+this+project%2C+it+has+been+intended+to+validate+the+standard+models+for+the+NMOT+(IEC+61853)+and+NOTC+(IEC+61215)+included+in+the+norms+regarding+PV+modules+in+plants%2C+for+its+use+in+BIPV+but+with+different+adjustment+parameters%2C+according+to+the+building+integration+of+the+module.+The+goodness-of-fit+and+the+obtained+parameters+vary+with+each+case%2C+depending+on+the+inclination+and+ventilation+of+the+module.+Since+that+temperature+affects+the+module%E2%80%99s+electrical+power+and+thus%2C+its+energy+output%2C+adjusting+the+modules+to+the+new+conditions+has+allowed+us+to+evaluate+how+acceptable+or+not+it+is+to+considerate+traditional+models.+To+do+so%2C+an+empiric+comparison+was+made+between+the+module%E2%80%99s+nominal+temperature+for+BIPV+and+the+theoretical+nominal+temperature+estimated+by+the+IEC+61215+and+IEC+61853+norms.+VII+For+this+study%2C+several+PV+modules+were+set+in+different+positions%2C+firstly+vertically+and+secondly+with+a+45%C2%BA+degree+inclination+with+respect+to+the+ground.+Temperature%2C+irradiance%2C+wind+speed+and+wind+direction+were+monitored+during+at+least+a+month+in+each+position.+It+must+be+highlighted+how+crucial+it+is+to+include+wind+parameterization+to+estimate+the+PV+module+temperature.+The+Data+obtained+was+adjusted+by+a+linear+regression+analysis+to+the+models+and+a+study+of+the+goodness-of-fit+has+been+made+using+statistics+and+the+SPSS+program.+As+a+result+of+the+study%2C+it+is+proven+that+the+nominal+temperature+expressions+of+both+norms+are+still+suitable+for+vertically-integrated+PV+modules%2C+fitting+best+those+that+resemble+a+rainscreen+fa%C3%A7ade.+However%2C+the+nominal+temperature+values+that+are+adjusted+through+a+regression+to+the+model+are+not.+It+has+been+analysed+what+error+has+been+made+in+each+annual+power+generation+estimation+when+considering+the+traditional+nominal+temperature+instead+of+the+experimentally+adjusted+temperature+for+each+building+integration+application.+These+errors+vary+between+1%25+for+vertical+ventilated+fa%C3%A7ade+and+7%25+for+the+vertical+non-ventilated+fa%C3%A7ade.&rft.publisher=E.T.S.I+de+Minas+y+Energ%C3%83%C2%ADa&rft.rights=https%3A%2F%2Fcreativecommons.org%2Flicenses%2Fby-nc-nd%2F3.0%2Fes%2F&rft.date=2018-09&rft.type=info%3Aeu-repo%2Fsemantics%2FbachelorThesis&rft.type=Final+Project&rft.type=PeerReviewed&rft.format=application%2Fpdf&rft.language=spa&rft.rights=info%3Aeu-repo%2Fsemantics%2FopenAccess&rft.identifier=https%3A%2F%2Foa.upm.es%2F52919%2F