Pump efficiency analysis for proper energy assessment in optimization of water supply systems.
"Water", v. 12
(n. 1);
p. 132.
ISSN 2073-4441.
https://doi.org/10.3390/w12010132.
| Título: | Pump efficiency analysis for proper energy assessment in optimization of water supply systems |
|---|---|
| Autor/es: |
|
| Tipo de Documento: | Artículo |
| Título de Revista/Publicación: | Water |
| Fecha: | 1 Enero 2020 |
| ISSN: | 2073-4441 |
| Volumen: | 12 |
| Número: | 1 |
| Materias: | |
| Palabras Clave Informales: | Design; Design policies; Optimization; Pump efficiency; Water distribution systems; Water supply systems |
| Escuela: | E.T.S.I. Caminos, Canales y Puertos (UPM) |
| Departamento: | Ingeniería Civil: Hidráulica, Energía y Medio Ambiente |
| Licencias Creative Commons: | Reconocimiento |
|
PDF (Portable Document Format)
- Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (3MB) |
© 2019 by the authors. Water supply systems need to be designed accounting for both construction and operational costs. When the installation requires water pumping, it is key for the operational costs to know how well the pump can perform. So far, pump efficiency has been considered using conservative values, in the absence of a better estimation. The aim of this paper was to improve determining the energy costs by clarifying what the value of the pump performance should be. For this, 226 commercial pumps were studied, registering the efficiency at the optimum operating point, as well as other variables such as the flow rate, height, and pump type. As a result, a strong relationship between the pump performance and the discharge flow was spotted. That allowed the generation of an empirical curve, which can be used by designers to anticipate what pump efficiency can be expected. The results are used in a simple case study using the Granados Optimization System. These achievements can be implemented in design policies for a better energy assessment in the optimization of water supply systems.
| ID de Registro: | 85793 |
|---|---|
| Identificador DC: | https://oa.upm.es/85793/ |
| Identificador OAI: | oai:oa.upm.es:85793 |
| URL Portal Científico: | https://portalcientifico.upm.es/es/ipublic/item/6112209 |
| Identificador DOI: | 10.3390/w12010132 |
| URL Oficial: | https://www.mdpi.com/2073-4441/12/1/132 |
| Depositado por: | iMarina Portal Científico |
| Depositado el: | 09 Ene 2025 10:54 |