Texto completo
|
PDF (Portable Document Format)
- Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (2MB) |
ORCID: https://orcid.org/0000-0002-9163-9357, Williams, Matthew St. Michael
ORCID: https://orcid.org/0000-0002-1309-6270, Kupolati, Halleluyah, Alonso Gómez, Víctor
ORCID: https://orcid.org/0000-0001-5107-4892, Gallardo Saavedra, Sara
ORCID: https://orcid.org/0000-0002-2834-5591, Redondo Plaza, Alberto
ORCID: https://orcid.org/0000-0002-2109-5614, Muñoz García, Miguel Angel
ORCID: https://orcid.org/0000-0002-3670-8989, Sánchez Pacheco, Francisco José
ORCID: https://orcid.org/0000-0002-0809-8300 and Hernández Callejo, Luis
ORCID: https://orcid.org/0000-0002-8822-2948
(2022).
A Power-Line Communication System Governed by Loop Resonance for Photovoltaic Plant Monitoring.
"Sensors", v. 22
(n. 23);
ISSN 1424-8220.
https://doi.org/10.3390/s22239207.
| Título: | A Power-Line Communication System Governed by Loop Resonance for Photovoltaic Plant Monitoring |
|---|---|
| Autor/es: |
|
| Tipo de Documento: | Artículo |
| Título de Revista/Publicación: | Sensors |
| Fecha: | Diciembre 2022 |
| ISSN: | 1424-8220 |
| Volumen: | 22 |
| Número: | 23 |
| Materias: | |
| Escuela: | E.T.S. de Ingeniería Agronómica, Alimentaria y de Biosistemas (UPM) |
| Departamento: | Ingeniería Agroforestal |
| Grupo Investigación UPM: | Técnicas Avanzadas en Agroalimentación LPF-TAGRALIA |
| Licencias Creative Commons: | Reconocimiento |
|
PDF (Portable Document Format)
- Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (2MB) |
Within this paper, a PLC system that takes advantage of the loop resonance of an entire DC-PV string configured as a circular signal path is developed and implemented. Low cost and extremely simple transceivers intended to be installed within each PV module of a string have been designed and successfully tested. In addition, an anti-saturation coil has been conceived to avoid saturation of the core when the entire DC current of the string flows through it. Bi-directional half-duplex communication was successfully executed with up to a 1 MHz carrier frequency (150 kbps bitrate), using a simple ASK modulation scheme. The transmission and reception performance are presented, along with the overall system cost in comparison to the previous literature.
| ID de Registro: | 86348 |
|---|---|
| Identificador DC: | https://oa.upm.es/86348/ |
| Identificador OAI: | oai:oa.upm.es:86348 |
| URL Portal Científico: | https://portalcientifico.upm.es/es/ipublic/item/9984750 |
| Identificador DOI: | 10.3390/s22239207 |
| URL Oficial: | https://www.mdpi.com/1424-8220/22/23/9207 |
| Depositado por: | Prof. Dr. Miguel Angel /M.A. Muñoz-García |
| Depositado el: | 20 Ene 2025 15:21 |
| Ultima Modificación: | 20 Ene 2025 15:21 |
Publicar en el Archivo Digital desde el Portal Científico