Precision of measurements of delayed slip in structural high-strength assemblies by contact and optical methods

Ortega Parreño, José Joaquín ORCID: https://orcid.org/0000-0001-8922-7882, Pan, Kaiming, Ruiz López, Gonzalo ORCID: https://orcid.org/0000-0002-0352-0701 and Zhang, Xiaoxin ORCID: https://orcid.org/0000-0002-7938-6924 (2024). Precision of measurements of delayed slip in structural high-strength assemblies by contact and optical methods. "Buildings", v. 14 (n. 4); p. 1046. ISSN 2075-5309. https://doi.org/10.3390/buildings14041046.

Descripción

Título: Precision of measurements of delayed slip in structural high-strength assemblies by contact and optical methods
Autor/es:
Tipo de Documento: Artículo
Título de Revista/Publicación: Buildings
Fecha: 1 Abril 2024
ISSN: 2075-5309
Volumen: 14
Número: 4
Materias:
ODS:
Palabras Clave Informales: Accuracy; Bolted Assembly; Bolted Connections; Contact Methods; Digital Image Correlation; Digital Image Correlations; Digital-Image-Correlation; Displacement Measurement; High-Strength; Image Correlation; Lvdt; Measurements Of; Measuring Precision; Optical Correlation; Optical Methods; Pixels; Slip Tolerance; Strain Measurement
Escuela: E.T.S.I. de Minas y Energía (UPM)
Departamento: Ingeniería Geológica y Minera
Licencias Creative Commons: Reconocimiento - Sin obra derivada - No comercial

Texto completo

[thumbnail of 10212380.pdf] PDF (Portable Document Format) - Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (3MB)

Resumen

Structural bolted connections of steel plates must fulfill the requirements specified by the standard EN 1090-2:2018 in the European Union. For the slip-resistant joints, the standard establishes the experimental procedure to obtain the delayed slip under a constant loading, which should not exceed 2 mu m from the first five minutes to three hours. However, the usual extensometers available in laboratories, like LVDTs, lack the necessary precision to obtain a reliable measurement of such a small displacement because, even if their resolution is 1 mu m, the scatter of repeated measurements of the same distance is normally higher. In contrast, the resolution and precision in optical methods like Digital Image Correlation (DIC) can be easily set under 1 mu m depending on the number of pixels covering the studied area and the performed subpixel interpolation. This work introduces the use of DIC for delayed slip tests. In comparison with an LVDT, it is verified that this technique is a valid alternative to measure displacements at that scale with a simpler experimental setup.

Proyectos asociados

Tipo
Código
Acrónimo
Responsable
Título
Gobierno de España
PID2019–110928RB–C31
Sin especificar
Ministerio de Ciencia e Innovación
Sin especificar
Sin especificar
2022-GRIN-34124
Sin especificar
Fondo Europeo de Desarrollo Regional
Sin especificar

Más información

ID de Registro: 90723
Identificador DC: https://oa.upm.es/90723/
Identificador OAI: oai:oa.upm.es:90723
URL Portal Científico: https://portalcientifico.upm.es/es/ipublic/item/10212380
Identificador DOI: 10.3390/buildings14041046
URL Oficial: https://www.mdpi.com/2075-5309/14/4/1046
Depositado por: iMarina Portal Científico
Depositado el: 12 Sep 2025 05:56
Ultima Modificación: 12 Sep 2025 06:18