Evaluation of the operating efficiency of a hybrid wind-hydro powerplant

Briongos, Francisco, Platero Gaona, Carlos Antonio ORCID: https://orcid.org/0000-0002-7007-2566, Sánchez Fernández, José Ángel ORCID: https://orcid.org/0000-0003-2425-5422 and Nicolet, Christophe (2020). Evaluation of the operating efficiency of a hybrid wind-hydro powerplant. "Sustainability", v. 12 (n. 2); p. 668. ISSN 2071-1050. https://doi.org/10.3390/su12020668.

Descripción

Título: Evaluation of the operating efficiency of a hybrid wind-hydro powerplant
Autor/es:
Tipo de Documento: Artículo
Título de Revista/Publicación: Sustainability
Fecha: 16 Enero 2020
ISSN: 2071-1050
Volumen: 12
Número: 2
Materias:
ODS:
Palabras Clave Informales: wind farm; pumped storage; isolated systems; power plant efficiency
Escuela: E.T.S.I. Caminos, Canales y Puertos (UPM)
Departamento: Ingeniería Civil: Hidráulica, Energía y Medio Ambiente
Licencias Creative Commons: Reconocimiento - Sin obra derivada - No comercial

Texto completo

[thumbnail of 6112235.pdf] PDF (Portable Document Format) - Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (3MB)

Resumen

This paper analyzes the operating efficiency of a hybrid wind-hydro power plant located in El Hierro Island. This plant combines a wind farm (11.48 MW) and a pumped storage power plant (11.32 MW). It was built with the aim of supplying the island demand from renewable energy instead of using existing diesel units. The paper discusses several operational strategies and proposes an efficiency metric. Using 10 min data, the operation of this power plant has been simulated. From these simulations (more than 50,000 for a year), the operating efficiency and the percentage of demand covered from renewable energy is obtained. The difference between the worst and the best strategy is a twofold increase in efficiency. Moreover, the results of the simulations are compared with the system operational history since June 2015 (when the wind-hydro power plant started operation) until 2018. These comparisons show a reasonable agreement between simulations and operational history.

Proyectos asociados

Tipo
Código
Acrónimo
Responsable
Título
Universidad Politécnica de Madrid
RP1604330010
Sin especificar
Sin especificar
Sin especificar

Más información

ID de Registro: 92954
Identificador DC: https://oa.upm.es/92954/
Identificador OAI: oai:oa.upm.es:92954
URL Portal Científico: https://portalcientifico.upm.es/es/ipublic/item/6112235
Identificador DOI: 10.3390/su12020668
URL Oficial: https://www.mdpi.com/2071-1050/12/2/668
Depositado por: iMarina Portal Científico
Depositado el: 16 Ene 2026 09:00
Ultima Modificación: 16 Ene 2026 09:00