Texto completo
Vista Previa |
PDF (Portable Document Format)
- Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (1MB) | Vista Previa |
ORCID: https://orcid.org/0000-0002-8743-6514
(2011).
Determination of Dipyrone in pharmaceutical preparations based on the chemiluminescent reaction of the quinolinic hydrazide-H2O2-vanadium (IV) system and flow injection analysis.
"Luminiscence", v. 27
(n. 1);
pp. 44-49.
ISSN 1522-7243.
https://doi.org/10.1002/bio.1323.
| Título: | Determination of Dipyrone in pharmaceutical preparations based on the chemiluminescent reaction of the quinolinic hydrazide-H2O2-vanadium (IV) system and flow injection analysis |
|---|---|
| Autor/es: |
|
| Tipo de Documento: | Artículo |
| Título de Revista/Publicación: | Luminiscence |
| Fecha: | Junio 2011 |
| ISSN: | 1522-7243 |
| Volumen: | 27 |
| Número: | 1 |
| Materias: | |
| ODS: | |
| Palabras Clave Informales: | quinolinic hydrazide;vanadium(IV);dipyrone;chemiluminescence;FIA |
| Escuela: | E.T.S.I. Industriales (UPM) |
| Departamento: | Ingeniería Química Industrial y del Medio Ambiente |
| Licencias Creative Commons: | Reconocimiento - Sin obra derivada - No comercial |
Vista Previa |
PDF (Portable Document Format)
- Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (1MB) | Vista Previa |
A rapid, economic and sensitive chemiluminescent method involving flow-injection analysis was developed for the determination of dipyrone in pharmaceutical preparations. The method is based on the chemiluminescent reaction between quinolinic hydrazide and hydrogen peroxide in a strongly alkaline medium, in which vanadium(IV) acts as a catalyst. Principal chemical and physical variables involved in the flow-injection system were optimized using a modified simplex method. The variations in the quantum yield observed when dipyrone was present in the reaction medium were used to determine the concentration of this compound. The proposed method requires no preconcentration steps and reliably quantifies dipyrone over the linear range 1–50 µg/mL. In addition, a sample throughput of 85 samples/h is possible. Copyright © 2011 John Wiley & Sons, Ltd.
| ID de Registro: | 12275 |
|---|---|
| Identificador DC: | https://oa.upm.es/12275/ |
| Identificador OAI: | oai:oa.upm.es:12275 |
| URL Portal Científico: | https://portalcientifico.upm.es/es/ipublic/item/5486826 |
| Identificador DOI: | 10.1002/bio.1323 |
| URL Oficial: | http://onlinelibrary.wiley.com/doi/10.1002/bio.132... |
| Depositado por: | Memoria Investigacion |
| Depositado el: | 30 Ago 2012 11:58 |
| Ultima Modificación: | 12 Nov 2025 00:00 |
Publicar en el Archivo Digital desde el Portal Científico